What aspects should be considered in the layout of air separation unit

What aspects should be considered in the layout of air separation unit
May 24, 2021
Author: DEAR AST

The air separation unit mainly consists of air compressor system, air precooling system, molecular sieve purification system, air separation cooling box and liquid storage tank area, and the three components are connected by inner pipe gallery.

 

The goal of air separation unit layout is safe, reliable and economical on the premise of meeting process requirements. At least the following aspects should be considered when designing the layout.

 

(1) Process requirements: meet the process requirements, consider the size of the equipment, etc.

 

(2) Customer demand: including the output size of the required devices, logistics direction, such as power supply, steam and cooling water sources, handover point of related products, future development demand, and requirements of structural buildings, such as machine building, office, control area, substation and maintenance workshop.

 

(3) unit conditions: site conditions should be considered, including unit size, meteorological conditions and surrounding environment.

 

(4) Site selection: it is necessary to consider the surrounding geographical environment and select the best site. The air separation unit should be on the downwind side of the annual minimum frequency wind direction of the pollution source.

 

(5) Greening requirements and layout optimization: greening coverage, unit landscaping, scheme comparison and selection.

 

(6) Design specification: meet the specification requirements, consider the minimum space and spacing requirements, including safety spacing, separation spacing, installation spacing, maintenance spacing and operation spacing. Safety distance refers to the minimum safety distance between hazard and person, while separation distance refers to the minimum distance between hazard and equipment.

DEAR Air Separation Solve YourWhat aspects should be considered in the layout of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top