1.Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.

 

2.After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.

 

3.The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. After tightening the nut, the bolt shall be exposed for about 2 nut distances.

 

4.The piping of air, nitrogen and crudenitrogen into air cooling columnand water cooling column shall be sealed to prevent backflow.

 

5.After the cooling water pump and freezing water pump are installed in place, check the concentricity of the water pump and the motor to ensure that the axis line of the water pump and the axis line of the motor must coincide.

 

6.The installation position of the water filter shall be convenient for the removal of the filter element and the maintenance and replacement of the filter element. After the single unit test run, the water filter should be removed and washed once, and then put into normal use.

 

7.The refrigeration unit shall be installed according to the installation requirements of the manufacturer.

DEAR Air Separation Solve YourPrecautions for installation of precooling systemYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top