Precautions for installation of precooling system

Precautions for installation of precooling system
Jan 15, 2021
Author: DEAR AST
Question Reply

1.Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.

 

2.After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.

 

3.The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. After tightening the nut, the bolt shall be exposed for about 2 nut distances.

 

4.The piping of air, nitrogen and crudenitrogen into air cooling columnand water cooling column shall be sealed to prevent backflow.

 

5.After the cooling water pump and freezing water pump are installed in place, check the concentricity of the water pump and the motor to ensure that the axis line of the water pump and the axis line of the motor must coincide.

 

6.The installation position of the water filter shall be convenient for the removal of the filter element and the maintenance and replacement of the filter element. After the single unit test run, the water filter should be removed and washed once, and then put into normal use.

 

7.The refrigeration unit shall be installed according to the installation requirements of the manufacturer.

DEAR Air Separation Solve YourPrecautions for installation of precooling systemYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
 The purpose of the blowing is to clean out the residual slag, aluminium chips and other debris from the piping and vessels. the air source for blowing is provided by the turbine compressor, and the air cooling tower must be activated. 3. blowing principle, first outside the tower, after the tower, blowing brush to be one after another, in the blowing with the air pressure: low pressure system. Should be maintained at 40 a 50kpa high pressure system: should be maintained at 250 ~ 400k...
2025.07.23
Due to improper adjustment of seal gas pressure during operation, liquid oxygen pump can not pump liquid or leak.   From the quality point of view, when the sealing pressure is too high, there will be gas leakage into the pump through the labyrinth seal, resulting in the impeller with gas or even idling, resulting in liquid injection or pressure drop; when the air pressure before sealing is too low, there will be liquid oxygen leakage.   From the quantity point of view, when (p1-p3...
2025.07.22
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top