Precautions for pearlite filling in air separation unit

Precautions for pearlite filling in air separation unit
Aug 18, 2026
Author: DEAR AST

1.Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed.

 

2.When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process.

 

3.The filled pearlite shall not be mixed with combustibles.

 

4.When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bagpearlite from entering the cold box.

 

5.After the pearlite is filled, the manhole shall be sealed.

DEAR Air Separation Solve YourPrecautions for pearlite filling in air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The load adjustment range of low pressure small air separation unit is related to the adjustment performance of the raw material compressor, the adjustment performance of the expander, the structural characteristics of the distillation tower and other factors. At present there are imported guide vane of the turbine air compressor flow adjustment range in 75-100%; adjustable nozzle of the turbine expander adjustment range can be in 65-100%. When oxygen is rich and the need to reduce oxygen produc...
2026.09.24
Causes of low air compressor efficiency of small air separation unit   There are many reasons for the low efficiency of air compressors, the common ones are: increase in suction temperature at any level, cooler leakage, decrease in grid frequency or voltage, blockage or increase in resistance of the compressor intercooler, gas leakage due to poor sealing, blockage or increase in resistance of the air filter, blockage or increase in resistance of the pipeline of the air separation equipmen...
2026.09.23
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top