There are two types of air separators, vertical and horizontal. The working principle of vertical air separator is that the mixture gas enters the housing and is cooled by evaporation tube, in which the refrigerant vapor condenses into liquid and remains at the bottom of the housing, while the non-condensable gas is discharged through the air outlet.The high-pressure liquid accumulated at the bottom enters the evaporation tube after being depressurized by the expansion valve, and the steam generated in the evaporation tube returns to the compressor. The working principle of the horizontal air separator is the same as that of the vertical air separator. After throttling pressure drop, the recovered refrigerant is returned from the lower return pipe to the second interlayer for utilization and the vapor generated after evaporation is returned to the compressor.
Faq of Air separator
More
What's the reason for using two-stage distillation column in air separation column?Usually, the air in the lower column is pre separated by the air separation column, which is rectified into liquid air which is rich in oxygen and pure nitrogen, and then further rectified in the upper column to obtain oxygen and nitrogen products. The connection between the upper and lower columns is the condensing evaporator. It uses the pressured nitrogen of the lower column to heat the liquid oxygen in the upper column, so as to evaporate the liquid oxygen while condensing the liquid nitrogen. The advantage of using two-stage distillation column is that the product has high extraction rate, and high purity oxygen and nitrogen can be obtained at the same time. Oxygen and nitrogen products can also be produced in a single-stage distillation column, but only one product can be produced separately. It is similar to the lower column of two-stage distillation column, in which pure nitrogen product can be
Nov 17, 2026
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
Sep 29, 2026
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top