Installation requirements of valves in cold box of air separation unit

Installation requirements of valves in cold box of air separation unit
Aug 11, 2023
Author: DEAR AST

1.Valves in cold box shall be installed after all vessels are in place and before pipeline installation.

 

2.The cold valve in the cold box shall be installed together with its corresponding support. The valve stem of cryogenic liquid valve should be inclined upward by 10°to 15°. When the pipe is welded with the valve body, the valve should be closed first. Take cooling measures to make the temperature of the valve body not higher than 200℃ during welding, so as to avoid the deformation of the valve seal and affect the normal use of the valve.

 

3.When installing the valve, pay attention to the arrow direction on the valve body, which should be consistent with the medium flow direction. On special occasions, some cold Angle Globe Valves and straight through heating valves outside the cold box make their directions opposite (according to the marks on the process flow chart).

 

4.The valve shall be opened and closed flexibly after installation. The valve opening and closing state shall be checked after the pipeline connection and during the cold test, and the valve shall be regarded as qualified if it is not stuck.

 

5.Before the installation of remote control valve, it is necessary to strictly check whether the command signal is synchronized with the action of the valve actuator: "fully open" and "fully closed" positions are correct, and record the relationship between the opening command and the actual opening of the valve.

 

6.For cold angle valve with sleeve, special tools shall be used to fasten flange bolts during cold test.

 

7.During the cold test of the low temperature pneumatic diaphragm control valve, special tools should be used to fasten the flange bolts.

 

8.After the valve is installed, mark the process tag number nearby (both inside and outside the cold box) and check the mark.

DEAR Air Separation Solve YourInstallation requirements of valves in cold box of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top