What are the technical requirements of the distillation column under the air separation plant?

What are the technical requirements of the distillation column under the air separation plant?
Aug 14, 2023
Author: DEAR AST
Question Reply

Answer: 1. The manufacture, inspection and acceptance of the lower distillation column comply with the provisions of JB/T2549-1994 "aluminum air separation equipment manufacturing technical specification" and JB/T4734-2002 "Aluminum Welding container.

2. the welding joints of Class A and B of containers should be tested 100% Ray to meet the second level requirements of JB/t4730-2005 non-destructive testing of pressure equipment; the welding joints of class C and D and those that cannot be detected by Ray should be 100% penetrated to meet the level I requirements of JB/t4730-2005.
3. after the container is manufactured and compounded with the main cold, use dry and clean air or nitrogen to 0. 69MPa conduct the barometric test on the surface pressure, keep the pressure for 30 min, and there should be no obvious deformation or leakage, and then reduce it to 0. 6MPa conduct the air tightness test under the pressure gauge, and keep the pressure Zh from leaking.
4. Test procedures refer to pressure vessel safety technology supervision regulations.
5. All parts must be oiled before assembly or after repair, and the cleanliness should meet the relevant requirements of JB/T 6869-1993 air separation equipment surface cleanliness.
6. The distance between the weld line of the tube and the plane of the tower plate is 90mm, and the strengthening nut should be riveted tightly after tightening to prevent loosening.

DEAR Air Separation Solve YourWhat are the technical requirements of the distillation column under the air separation plant?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
What is the principle of return slop nitrogen removing frozen water and carbon dioxide?
2026.05.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top