What are the technical requirements of the distillation column under the air separation plant?

What are the technical requirements of the distillation column under the air separation plant?
Aug 14, 2023
Author: DEAR AST
Question Reply

Answer: 1. The manufacture, inspection and acceptance of the lower distillation column comply with the provisions of JB/T2549-1994 "aluminum air separation equipment manufacturing technical specification" and JB/T4734-2002 "Aluminum Welding container.

2. the welding joints of Class A and B of containers should be tested 100% Ray to meet the second level requirements of JB/t4730-2005 non-destructive testing of pressure equipment; the welding joints of class C and D and those that cannot be detected by Ray should be 100% penetrated to meet the level I requirements of JB/t4730-2005.
3. after the container is manufactured and compounded with the main cold, use dry and clean air or nitrogen to 0. 69MPa conduct the barometric test on the surface pressure, keep the pressure for 30 min, and there should be no obvious deformation or leakage, and then reduce it to 0. 6MPa conduct the air tightness test under the pressure gauge, and keep the pressure Zh from leaking.
4. Test procedures refer to pressure vessel safety technology supervision regulations.
5. All parts must be oiled before assembly or after repair, and the cleanliness should meet the relevant requirements of JB/T 6869-1993 air separation equipment surface cleanliness.
6. The distance between the weld line of the tube and the plane of the tower plate is 90mm, and the strengthening nut should be riveted tightly after tightening to prevent loosening.

DEAR Air Separation Solve YourWhat are the technical requirements of the distillation column under the air separation plant?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The load adjustment range of low pressure small air separation unit is related to the adjustment performance of the raw material compressor, the adjustment performance of the expander, the structural characteristics of the distillation tower and other factors. At present there are imported guide vane of the turbine air compressor flow adjustment range in 75-100%; adjustable nozzle of the turbine expander adjustment range can be in 65-100%. When oxygen is rich and the need to reduce oxygen produc...
2026.09.24
Causes of low air compressor efficiency of small air separation unit   There are many reasons for the low efficiency of air compressors, the common ones are: increase in suction temperature at any level, cooler leakage, decrease in grid frequency or voltage, blockage or increase in resistance of the compressor intercooler, gas leakage due to poor sealing, blockage or increase in resistance of the air filter, blockage or increase in resistance of the pipeline of the air separation equipmen...
2026.09.23
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top