How to shorten the start-up time of the full low-voltage air separation plant in the self-cleaning process?

How to shorten the start-up time of the full low-voltage air separation plant in the self-cleaning process?
Aug 15, 2023
Author: DEAR AST
Question Reply

The heat capacity of Plate-fin switching heat exchanger is small,Air separation equipmentThe start time is short, at 30 ~ 36 H level; the start time of the air separation unit with stone cooler needs 48 ~ 60h.
In terms of operation, master the essentials of operation: prevent moisture and carbon dioxide from being brought into the tower; strictly control the temperature difference between the cold end and the hot end; pay attention to the cooling of the main cooling; give full play to the refrigeration capacity of multiple expansion machines; reasonable allocation and utilization of cooling capacity, depending on the potential of the equipment itself to shorten the start-up time.
Because of the large heat capacity of the stone cooler, it takes quite a long time to cool down to normal temperature after heating. The air of the turbine air compressor can be used to blow the stuffing to near normal temperature before starting the expansion machine, and hot air can be discharged from the automatic valve box. In this way, the precooling time of the stuffing can be shortened.
In addition, using external cold source is also an effective way to shorten the start-up time. When the main cooling is over and liquid appears, input liquid oxygen, liquid or liquid nitrogen from the outside. The method of infusion is to connect the liquid source with the liquid oxygen discharge valve, open the liquid oxygen discharge valve and inject the external liquid into the main cooling. When the main cold liquid level reaches the normal liquid level, the infusion can be stopped, and the air separation tower can enter the stage of purging. With this infusion technology, the start-up time can be shortened by more than 12 hours. This is a very economical method, which has been applied in many units and has achieved practical energy saving effect.
The source of the liquid can be provided by another running air separation plant; it can also be discharged into the storage tank for standby when parking; it can also be introduced from the low temperature storage tank of liquid oxygen.

DEAR Air Separation Solve YourHow to shorten the start-up time of the full low-voltage air separation plant in the self-cleaning process?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top