Treatment of low temperature after expander of air separation unit

Treatment of low temperature after expander of air separation unit
Jun 01, 2026
Author: DEAR AST

If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.

DEAR Air Separation Solve YourTreatment of low temperature after expander of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top