1.The purpose of purging is to purge the welding slag and dirt left in the pipeline and container.

 

2.The principle of purging is doing the outside columnfirstly,and the inside column after. The purging should be carried out one pipeline by one.

 

3.When purging the system, the filter core on the equipment inlet pipe should be removed.

 

4.When purging the pipe outside the cold box, all the valves connected with the cold box should be disconnected to prevent dirt from entering the valve and column.

 

5.The purging of each system should be repeated for many times. The purging time shall not be less than 4 hours.

 

6.To check whether the purging is complete, wet white filter paper or white cloth shouldbe used to placeat the outlet of purging. After 5 minutes, it is qualified if it is clean and free of obvious mechanical impurities.

DEAR Air Separation Solve YourPrecautions for pipeline purging of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Why only cryogenic air separation equipment can be selected for large industrial gas?
2026.03.19
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top