1.The purpose of purging is to purge the welding slag and dirt left in the pipeline and container.

 

2.The principle of purging is doing the outside columnfirstly,and the inside column after. The purging should be carried out one pipeline by one.

 

3.When purging the system, the filter core on the equipment inlet pipe should be removed.

 

4.When purging the pipe outside the cold box, all the valves connected with the cold box should be disconnected to prevent dirt from entering the valve and column.

 

5.The purging of each system should be repeated for many times. The purging time shall not be less than 4 hours.

 

6.To check whether the purging is complete, wet white filter paper or white cloth shouldbe used to placeat the outlet of purging. After 5 minutes, it is qualified if it is clean and free of obvious mechanical impurities.

DEAR Air Separation Solve YourPrecautions for pipeline purging of air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When the demand for oxygen increases higher than the normal working condition, more liquid oxygen is extracted from the liquid oxygen storage tank, pressurized to the required pressure by the liquid oxygen pump and sent into the main heat exchanger after gasification and reheating, and the liquid oxygen stored in the liquid oxygen storage tank is consumed. At the same time, the flow of low-pressure expander will be reduced, and more cold volume will be recovered by high-pressure nitrogen and the...
2026.09.22
Brief description of the molecular sieve problem The purifier CO₂ suddenly started to run abnormally and suddenly went out of range in liquid air separation plants, the dew point never changed significantly. The dew point did not change significantly. In order to ensure that the other molecular sieve had enough time to regenerate, the time could not be shortened any further. At this point there was a relatively stable situation with no further deterioration. Check the trend graph for a cold bl...
2026.09.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top