Single stage and double stage distillation column in air separation plant

Single stage and double stage distillation column in air separation plant
Oct 23, 2025
Author: DEAR AST
Question Reply

In the distillation column of air separation, the air is usually pre separated in the lower column, and then distilled into oxygen rich liquid air and pure nitrogen, and then further distillation in the upper column to obtain oxygen and nitrogen products. As a condensing evaporator connecting the upper and lower columns, the pressure nitrogen of the lower column is used to heat the liquid oxygen of the upper column. When the liquid oxygen is evaporated, the gas nitrogen is condensed. The two-stage distillation column can make oxygen and nitrogen products obtain higher extraction rate and higher purity. The working principle of single-stage distillation column is similar to that of the lower column of two-stage distillation column. Oxygen enriched liquid air is at the bottom of the column, and pure nitrogen gas can be obtained at the top of the column. The single-stage distillation column can't separate the air perfectly, so it is seldom used in practice. However, because of its simple structure, it is sometimes used in small air separation unit for producing single product. 

DEAR Air Separation Solve YourSingle stage and double stage distillation column in air separation plantYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top