Related factors of regulating operation load of low pressure air separation unit

Related factors of regulating operation load of low pressure air separation unit
Oct 30, 2025
Author: DEAR AST
Question Reply

The load regulation range of low pressure air separation unit is related to the regulating performance of feed air compressor, the regulating performance of expander and the structural characteristics of distillation column. At present, the flow regulation range of turbine air compressor with inlet guide vane is 75% to 100%, and that of turbocharged expander with adjustable nozzle is 65% to 100%. Next, the most important thing is to adjust the residual of the distillation column. At present, the load regulation range of distillation column with structured packing can reach 50% - 100%, while that of traditional sieve tray column is 70% - 100%. If the load is too low, it will cause liquid leakage because the speed of steam passing through the sieve is too slow.

 

When oxygen is sufficient and the oxygen output needs to be reduced, first reduce the output of oxygen products, then reduce the air flow accordingly, and adjust the expansion air volume according to the main cooling level. The liquid gas and liquid nitrogen control valves sent to the upper tower should also be closed according to the distillation conditions. It should be noted that the whole operation should be completed slowly and gradually, so as to keep the distillation conditions stable during the reduction process.

 

If there is a liquid oxygen storage system, reducing the oxygen production can increase the production of liquid oxygen and make the storage of liquid oxygen more convenient. The oxygen output can be reduced first, then the expansion air volume can be increased, and the liquid oxygen extraction amount can be increased under the condition of keeping the main cooling liquid level unchanged. In order to maintain the stability of upper column distillation, some expansion air can be bypassed if necessary.

DEAR Air Separation Solve YourRelated factors of regulating operation load of low pressure air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top