1.Enter the work area,wear all kinds of labor protection equipment; check the surrounding working environment; confirm the tools and machines; prohibit the use of defective tools.

 

2.When using the sledge hammer, it is forbidden to wear gloves; it is strictly forbidden to stand in the range of before, after, up, down, left and right of the sledge hammer, and no one is allowed to stand on the opposite side to prevent injury.

 

3.Before welding operation, it is necessary to carefully check whether the electric welding tools used are insulated, whether the primary and secondary wires of the welding machine are damaged, and whether the grounding wire is in good condition; insulating gloves must be worn to prevent the occurrence of electric shock accidents when the welding machine stops power transmission and switches on.

 

4.The safety protection facilities of oxygen cylinder and acetylene cylinder should be complete and reliable. When working, the distance between oxygen cylinder and acetylene cylinder should be more than 5 meters; acetylene cylinder should not be put down for use; oxygen cylinder and acetylene cylinder should not be mixed; throwing, rolling and impact are strictly prohibited during loading and unloading; there should be no oil stain on the bottle mouth and body; the upper part of oxygen and acetylene cylinder should be exposed to the sun.

 

5.It is strictly forbidden to use lifting equipment to lift oxygen cylinder and acetylene cylinder, and hanging cage should be used. The oxygen cylinder and acetylene cylinder must be placed 10 meters away from the hotwork It is strictly forbidden to place the oxygen cylinder and acetylene cylinder under the hot work position and other places close to the fire source to avoid explosion.

 

6.When using tricycles and tractors to transport tools, materials and spare parts,the drivers must hold a motor vehicle driver's license before driving. During driving, should strictly abide by the traffic rules. The speed should not be too fast, and the tractor is forbidden to carry people.

DEAR Air Separation Solve YourSafety measures for routine operationYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top