当前位置: Home / Faq / Large air separation FAQ /

Prevention of incorrect shutdown of air separation plant

Prevention of incorrect shutdown of air separation plant
Jul 09, 2024
Author: DEAR AST
Question Reply

Air separation plant is an important supporting facility for large-scale industrial enterprises, such as chemical industry, smelting industry, electronics industry and energy industry. Its operation condition is very important to the enterprise. In the actual production, the air separation plant is often be shut down by mistake due to many factors, such as instrument control incorrect interlocking, manual incorrect operation or network voltage fluctuation, which causes great losses to the enterprise. Here are a few preventive measures for incorrect shutdown.

 

1.Prevention of instrument and control system incorrect interlock: the common factors that causeinstrument and control system incorrect interlock include alternating magnetic field interference, detection component failure and unreasonable interlock parameter setting, etc.

 

a.In order to reduce the influence of alternating magnetic field on the signal of I & C system, when installing and using large electrical plant, welding machine, interphone and remote control device of plant, it should bekeptaway from the measuring elements of I & C, and regularly test the shielding and grounding performance of I & C cable.

 

b.Through the modification of the interlock, the interlock parameters should beset reasonably. The reliability of the instrument and control elements is enhanced, and the incorrect interlock shutdown caused by the failure of a single measuring element is avoided.

 

2.Prevention of manual misoperation: the common forms of manual misoperation include data input error, improper operation procedures in emergency state, misoperation of safety protection facilities, unconscious misoperation, etc. In order to prevent the occurrence of manual misoperation, the operation authority and scope shall be set at the key control points, and good operation habits shall be formed. Specifically, the programmed operation can be carried out through the preparation of post operation procedure card and process post emergency response card and other measures. In addition, it is necessary to carry out joint security system for post employees to strengthen their safety responsibility awareness.

 

3.Disturbance of networkvoltage fluctuation factor to plant: to minimize grid "sloshing point"for the interference of mechanical and electrical plant, the time relay with reset terminal can be adopted. In the moment of sloshing, when the speed of main motor has not decreased with the help of inertia, the voltage will return to normal, and the original main motor will be automatically reset and started.

 

In order to prevent the air separation plant from incorrect shutdown, it is necessary to start from many aspects such as the change of staff awareness, the improvement of skills, the refinement of plant management and the improvement of the stability of control system, so as to extend the continuous operation cycle of air separation plant and reduce the production and operation costs.

DEAR Air Separation Solve YourPrevention of incorrect shutdown of air separation plantYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquefaction of gases can be divided into forward and reverse cycles. The forward cycle process is the absorption of heat from the higher temperature external heat source and the release of heat to the lower temperature external heat source. The reverse cycle is when the mass draws heat from a lower temperature external heat source and releases it to a higher temperature external heat source. The forward cycle converts heat energy into mechanical energy and the reverse cycle converts mechani...
2025.09.26
Distillation is using the different boiling points of the two substances to condense the mixed steam and vaporize the mixed liquid repeatedly to achieve gas separation. For a mixed liquid composed of two substances with different boiling points, when the heat absorption part evaporates, the volatile components will evaporate more, while the mixed steam will give off heat and partially condense, the non volatile components will condense more. If the saturated steam with higher temperature is mixed with the saturated liquid with lower temperature, the steam will release heat and partially condense, and the liquid will absorb heat part of it evaporates. If after a round of partial evaporation and partial condensation, the steam and liquid with higher concentration will contact with the steam and liquid with different temperature respectively, and then partial condensation and partial evaporation will occur again. This process will be repeated for many times, and finally gas separation
2025.09.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top