Prevention of incorrect shutdown of air separation plant

Prevention of incorrect shutdown of air separation plant
Jul 09, 2024
Author: DEAR AST
Question Reply

Air separation plant is an important supporting facility for large-scale industrial enterprises, such as chemical industry, smelting industry, electronics industry and energy industry. Its operation condition is very important to the enterprise. In the actual production, the air separation plant is often be shut down by mistake due to many factors, such as instrument control incorrect interlocking, manual incorrect operation or network voltage fluctuation, which causes great losses to the enterprise. Here are a few preventive measures for incorrect shutdown.

 

1.Prevention of instrument and control system incorrect interlock: the common factors that causeinstrument and control system incorrect interlock include alternating magnetic field interference, detection component failure and unreasonable interlock parameter setting, etc.

 

a.In order to reduce the influence of alternating magnetic field on the signal of I & C system, when installing and using large electrical plant, welding machine, interphone and remote control device of plant, it should bekeptaway from the measuring elements of I & C, and regularly test the shielding and grounding performance of I & C cable.

 

b.Through the modification of the interlock, the interlock parameters should beset reasonably. The reliability of the instrument and control elements is enhanced, and the incorrect interlock shutdown caused by the failure of a single measuring element is avoided.

 

2.Prevention of manual misoperation: the common forms of manual misoperation include data input error, improper operation procedures in emergency state, misoperation of safety protection facilities, unconscious misoperation, etc. In order to prevent the occurrence of manual misoperation, the operation authority and scope shall be set at the key control points, and good operation habits shall be formed. Specifically, the programmed operation can be carried out through the preparation of post operation procedure card and process post emergency response card and other measures. In addition, it is necessary to carry out joint security system for post employees to strengthen their safety responsibility awareness.

 

3.Disturbance of networkvoltage fluctuation factor to plant: to minimize grid "sloshing point"for the interference of mechanical and electrical plant, the time relay with reset terminal can be adopted. In the moment of sloshing, when the speed of main motor has not decreased with the help of inertia, the voltage will return to normal, and the original main motor will be automatically reset and started.

 

In order to prevent the air separation plant from incorrect shutdown, it is necessary to start from many aspects such as the change of staff awareness, the improvement of skills, the refinement of plant management and the improvement of the stability of control system, so as to extend the continuous operation cycle of air separation plant and reduce the production and operation costs.

DEAR Air Separation Solve YourPrevention of incorrect shutdown of air separation plantYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top