What is the common fault of pneumatic film regulating valve?

What is the common fault of pneumatic film regulating valve?
Apr 17, 2024
Author: DEAR AST
Question Reply

Leakage is the easiest failure of regulating valve during operation. Some leak at the welding place, and some leak at the sealing place of the stuffing. When leakage occurs at the welding site, repair welding can be done during overhaul; when leakage occurs at the sealing site of the stuffing, new stuffing can be replaced. Sometimes the film of the film actuator is damaged, and the valve stem can't act normally with the air pressure signal, so it needs to be replaced with a new film.
In order to avoid the deformation of the valve stem affecting the regulating function, it is better to stand on the pipeline when installing the regulating valve. Low temperature filmControl valveIt is not suitable to install horizontally, and an angle above 150 should be formed with the level so that the sealing place of the stuffing is not affected by the liquid. The slanting valve must be lifted.
When operating, always pay attention to whether the regulating valve gets stuck. The sealing filler should not be screwed too tightly in case of affecting the movement of the valve stem. When the adjusting range of the regulating valve is not enough, bypass valve can be added beside the regulating valve to enlarge the adjusting range, or the regulating valve with large range can be used instead.

DEAR Air Separation Solve YourWhat is the common fault of pneumatic film regulating valve?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Water evaporation, wind-blown losses and other situations occurring in industrial circulating cooling water system operation, resulting in the continuous concentration of circulating water, then the salts contained therein exceed the standard, anions and cations increase, PH value changes significantly, resulting in the deterioration of water quality. The temperature of the circulating water rises and the PH value and nutrients increase, which is conducive to the reproduction of microorganisms. ...
2026.06.03
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top