What is the common fault of pneumatic film regulating valve?

What is the common fault of pneumatic film regulating valve?
Apr 17, 2024
Author: DEAR AST
Question Reply

Leakage is the easiest failure of regulating valve during operation. Some leak at the welding place, and some leak at the sealing place of the stuffing. When leakage occurs at the welding site, repair welding can be done during overhaul; when leakage occurs at the sealing site of the stuffing, new stuffing can be replaced. Sometimes the film of the film actuator is damaged, and the valve stem can't act normally with the air pressure signal, so it needs to be replaced with a new film.
In order to avoid the deformation of the valve stem affecting the regulating function, it is better to stand on the pipeline when installing the regulating valve. Low temperature filmControl valveIt is not suitable to install horizontally, and an angle above 150 should be formed with the level so that the sealing place of the stuffing is not affected by the liquid. The slanting valve must be lifted.
When operating, always pay attention to whether the regulating valve gets stuck. The sealing filler should not be screwed too tightly in case of affecting the movement of the valve stem. When the adjusting range of the regulating valve is not enough, bypass valve can be added beside the regulating valve to enlarge the adjusting range, or the regulating valve with large range can be used instead.

DEAR Air Separation Solve YourWhat is the common fault of pneumatic film regulating valve?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top