What is the common fault of pneumatic film regulating valve?

What is the common fault of pneumatic film regulating valve?
Apr 17, 2024
Author: DEAR AST
Question Reply

Leakage is the easiest failure of regulating valve during operation. Some leak at the welding place, and some leak at the sealing place of the stuffing. When leakage occurs at the welding site, repair welding can be done during overhaul; when leakage occurs at the sealing site of the stuffing, new stuffing can be replaced. Sometimes the film of the film actuator is damaged, and the valve stem can't act normally with the air pressure signal, so it needs to be replaced with a new film.
In order to avoid the deformation of the valve stem affecting the regulating function, it is better to stand on the pipeline when installing the regulating valve. Low temperature filmControl valveIt is not suitable to install horizontally, and an angle above 150 should be formed with the level so that the sealing place of the stuffing is not affected by the liquid. The slanting valve must be lifted.
When operating, always pay attention to whether the regulating valve gets stuck. The sealing filler should not be screwed too tightly in case of affecting the movement of the valve stem. When the adjusting range of the regulating valve is not enough, bypass valve can be added beside the regulating valve to enlarge the adjusting range, or the regulating valve with large range can be used instead.

DEAR Air Separation Solve YourWhat is the common fault of pneumatic film regulating valve?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why do molecular sieves in small air separation unit use bunk beds? Molecular sieve purifiers are used in both small and large air separation plants to purify the air. carbon dioxide, acetylene, and various hydrocarbons. Some molecular sieves small air separation unit use a double bed because the adsorption capacity of activated alumina is relatively large for air with high water content, but as the water content of the air decreases, the adsorption capacity decreases rapidly. The molecular s...
2026.01.29
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top