In which parts of switching heat exchanger are easy to leak, what is the cause, how to check and how to deal with it?

In which parts of switching heat exchanger are easy to leak, what is the cause, how to check and how to deal with it?
Mar 29, 2024
Author: DEAR AST
Question Reply

Switching heat exchanger of air separation plantThe most likely place to leak is the weld seam, especially the joint of the head and the pipeline. Most of the causes of leakage are the quality problems of manufacture and installation, which are also related to maintenance.Switching heat exchangerThe working condition is poor, not only affected by alternating airflow, but also the airflow temperature changes a lot, in the long-term operation, the weak parts are easy to cause leakage.
Therefore, the welding quality should be strictly guaranteed during manufacture and installation. After installation, strict leak detection and pressure test must be carried out before driving, and problems should be dealt with timely to avoid passivity after driving.
Check in operationSwitching heat exchangerThere are three ways of leakage or not:
1) flow method. When a large amount of leakage occurs between the channel of product oxygen or product nitrogen and air channel, the output of oxygen or nitrogen increases obviously. The air intake should also increase. At the same time, the air pressure decreases and the upper tower pressure increases.
2) purity method. When there is a small amount of leakage between the oxygen and nitrogen channels of the products and the air channels, it can be judged by the results of the product purity analysisSwitching heat exchangerThe purity of the product declines.
3) temperature method. When leakage occurs between the air channel and the sewage and nitrogen channel, the temperature in the middle part will change obviously, and it can be judged from the temperature change which unit has the leakage. Moreover, the air intake will also increase.
Repair welding should be conducted after identifying the leakage parts. If there is an internal leakage in a single channel, the channel can be sealed. If the serious leakage cannot be solved, replace thisHeat exchangerUnit.

DEAR Air Separation Solve YourIn which parts of switching heat exchanger are easy to leak, what is the cause, how to check and how to deal with it?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What's the reason for using two-stage distillation column in air separation column?Usually, the air in the lower column is pre separated by the air separation column, which is rectified into liquid air which is rich in oxygen and pure nitrogen, and then further rectified in the upper column to obtain oxygen and nitrogen products. The connection between the upper and lower columns is the condensing evaporator. It uses the pressured nitrogen of the lower column to heat the liquid oxygen in the upper column, so as to evaporate the liquid oxygen while condensing the liquid nitrogen. The advantage of using two-stage distillation column is that the product has high extraction rate, and high purity oxygen and nitrogen can be obtained at the same time. Oxygen and nitrogen products can also be produced in a single-stage distillation column, but only one product can be produced separately. It is similar to the lower column of two-stage distillation column, in which pure nitrogen product can be
2026.11.17
Answer: to judge whether the air separation unit is advanced or not, it mainly depends on three hard indicators, combined with the comprehensive evaluation of the intelligent level. 1. Core evaluation index -Unit power consumption: commonly measured in kwh/nm ³ o ɑ, it is the operating cost index that customers are most concerned about; The larger the scale and the higher the purity, the lower the unit energy consumption. -Oxygen extraction rate: it reflects the utilization efficiency of raw air. The higher the extraction rate, the more electricity is saved. The cryogenic method is usually better than the simple process. -Operation stability and load regulation range: whether the load can be changed smoothly between 30% and 110% will directly affect the ability of adaptive gas fluctuation. 2. Embodiment of the advanced nature of Deere air separation -The eighth generation of intelligent air separation technology: make system optimization in process organization and equipment matching,
2026.11.16
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top