To eliminateCompressorThe vibration generally starts from the following ways:
1. The static balance and dynamic balance of moving parts should be corrected, otherwise it will cause congenital vibration factors.
2. The concentricity of compressor, motor or diesel engine should be correct.
3. The foundation of compressor should be constructed in strict accordance with the design drawings. No rigid connection is allowed between the foundation and any structure of the building.
4. Because of the vibration caused by airflow pulsation, the accessory equipment and pipeline must have firm support and be fastened with it. The cantilever frame should be reinforced support and plugged tightly with padding iron.
5. The tightening force of the anchor screw of the machine should be consistent;
6. The rack (engine base) should have enough stiffness.