Why do some distillation towers draw sewage nitrogen while some do not?

Why do some distillation towers draw sewage nitrogen while some do not?
Jul 28, 2023
Author: DEAR AST
Question Reply

As for the oxygen generator in the flow of switching heat exchanger, in order to achieve the self-elimination of moisture and carbon dioxide, the amount of dirt and nitrogen is relatively large, so the condition of not freezing can be guaranteed. Therefore, the amount of pure gas and nitrogen products is relatively small, it can only reach 1.3 times of the output of gas and oxygen at most, so the amount of pure liquid nitrogen provided by the lower tower is less, so a stream of sewage nitrogen can be extracted to the upper tower, which increases the reflux ratio of the distillation section of the upper tower, it has greater rectification potential, thus allowing more inflated air to enter the upper tower to prevent inflated air from passing by and affecting oxygen extraction rate.
As for the oxygen generator in the process of purification, pressurization and expansion of molecular sieve, the quantity of pure gas and nitrogen products has been greatly increased due to the lack of self-cleaning restriction. In addition to the quantity of dirt and nitrogen used for regeneration of the molecular sieve purifier, both can be sent out as pure gas and nitrogen products, and the ratio of pure nitrogen production to oxygen production can reach 3 ~ 3.5. In this way, the lower tower needs a larger reflux ratio to ensure the amount and purity of pure liquid nitrogen, and then it is sent to the upper tower as the reflux liquid.
In addition, because this process adopts pressurized expansion, the unit refrigerating capacity of the expansion working medium is relatively high, under the premise of compensating the same cold loss, the required expansion capacity is relatively small, generally, it will not exceed the air volume allowed by the upper tower, therefore, it is not necessary to extract sewage nitrogen to directly increase the reflux ratio of the distillation section. At the same time, because there is no sewage and nitrogen pumping, the lower tower reduces the pumping outlets, pipelines and valves, and simplifies the process.
In a word, oxygen generator with high production of pure gas and nitrogen generally does not draw sewage and nitrogen. In the case of pressurized expansion and small expansion, it is even more unnecessary to draw sewage nitrogen from the lower tower.

DEAR Air Separation Solve YourWhy do some distillation towers draw sewage nitrogen while some do not?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top