What is the difference between full heating of air separation equipment in the cold state and in the hot state, and what is the difference in the operation method?

What is the difference between full heating of air separation equipment in the cold state and in the hot state, and what is the difference in the operation method?
Jul 31, 2023
Author: DEAR AST

Full heating in the cold state is a heating operation after stopping. The main purpose is to remove the residual moisture, carbon dioxide, acetylene and other impurities, for the next cycle of long-term operation or maintenance.
Comprehensive warming in hot condition is the warming operation before driving. Its main purpose is to remove moisture and some solid impurities.
Full heating in the hot state, the temperature difference in the tower is less, generally less than 60 ℃; while the cold state heating, the temperature difference is more than 200 ℃. In order to prevent the tower inner vessel, pipeline thermal stress is too large and damage, the cold state of the full heating and the hot state of the full heating in the operating procedures are different.
The procedure of full-scale heating in cold state is shutdown - liquid discharge - static - cold blowing - heating - system blowing out. The end point of heating is the outlet temperature of the heated gas until it reaches room temperature. Under the hot state, the full heating operation procedure is divided into heating and blowing off two steps. In order to completely remove moisture to achieve the purpose of drying, the outlet temperature of the heated gas should be higher than room temperature. In order to remove the solid debris, the blowing off part of the full heating operation in the hot state is more important.
DEAR Air Separation has in-depth analysis and research on air separation equipment technology to provide customers with better design solutions for air separation projects.

DEAR Air Separation Solve YourWhat is the difference between full heating of air separation equipment in the cold state and in the hot state, and what is the difference in the operation method?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top