Switching purification process what problems should be paid attention to when the air separation plant restarts after a short-term stop?

Switching purification process what problems should be paid attention to when the air separation plant restarts after a short-term stop?
Mar 08, 2024
Author: DEAR AST
Question Reply

Switching purification processAir separation equipmentIt refers to self-cleaning of moisture and carbon dioxide in the passageway of switching Plate-fin Heat Exchanger (or cooler) through switching valve. Switching purification process the air separation equipment mostly adopts the method of circulation or extraction to reduce the temperature difference of the cold end of the Plate-fin Heat Exchanger (or the cooler); it adopts the expansion heat exchanger to recover the cooling, further reduce the temperature of the expansion gas; use the liquid supercooler to further reduce the liquid temperature of the throttle entering the upper tower. Therefore, switching purification processAir separation equipmentWhen restarting after short-term parking, attention should be paid:
1) before recovery, determine the start-up circuit according to the temperature recovery situation at the cold end;
2) there is a liquid supercoolerAir separation equipment, Drain a part of the liquid from the lower tower and the main cooling before starting to prevent the liquid air supercooler from blocking;
3) when the temperature at the cold end reaches-150℃, the circular flow should be reduced as much as possible to prevent carbon dioxide from blocking the circulation channel;
4) shorten the switching time and reduce the cold end temperature as soon as possible;
5) when the temperature at the cold end reaches the technological requirements and the air separation starts into the fourth stage, the expansion heat exchanger should not be started first to prevent carbon dioxide from blocking the expansion heat exchanger.

DEAR Air Separation Solve YourSwitching purification process what problems should be paid attention to when the air separation plant restarts after a short-term stop?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
How to maintain the operation and maintenance intercooler box of air separation equipment?
2026.01.26
The amount of liquid nitrogen removed from the lower column of the air separation unit will affect the purity of the liquid nitrogen in the lower column and the oxygen enriched liquid air at the bottom of the column. When the liquid nitrogen removal amount of the lower column increases, the reflux liquid participating in the heat and mass exchange of the lower column will be reduced, the temperature rise of the rising steam on the column plate will be correspondingly reduced, the condensation of the rising steam will not be sufficient, the oxygen component will be condensed less, the purity of nitrogen at the column top will be reduced, and the purity of liquid nitrogen will be naturally reduced. At the same time, the temperature rise of the downflow liquid will increase, the liquid evaporation will be more sufficient, more nitrogen components will be evaporated to the top of the column, and the purity of the liquid air at the bottom of the column will be improved accordingly.
2026.01.23
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top