Switching purification process what problems should be paid attention to when the air separation plant restarts after a short-term stop?

Switching purification process what problems should be paid attention to when the air separation plant restarts after a short-term stop?
Mar 08, 2024
Author: DEAR AST
Question Reply

Switching purification processAir separation equipmentIt refers to self-cleaning of moisture and carbon dioxide in the passageway of switching Plate-fin Heat Exchanger (or cooler) through switching valve. Switching purification process the air separation equipment mostly adopts the method of circulation or extraction to reduce the temperature difference of the cold end of the Plate-fin Heat Exchanger (or the cooler); it adopts the expansion heat exchanger to recover the cooling, further reduce the temperature of the expansion gas; use the liquid supercooler to further reduce the liquid temperature of the throttle entering the upper tower. Therefore, switching purification processAir separation equipmentWhen restarting after short-term parking, attention should be paid:
1) before recovery, determine the start-up circuit according to the temperature recovery situation at the cold end;
2) there is a liquid supercoolerAir separation equipment, Drain a part of the liquid from the lower tower and the main cooling before starting to prevent the liquid air supercooler from blocking;
3) when the temperature at the cold end reaches-150℃, the circular flow should be reduced as much as possible to prevent carbon dioxide from blocking the circulation channel;
4) shorten the switching time and reduce the cold end temperature as soon as possible;
5) when the temperature at the cold end reaches the technological requirements and the air separation starts into the fourth stage, the expansion heat exchanger should not be started first to prevent carbon dioxide from blocking the expansion heat exchanger.

DEAR Air Separation Solve YourSwitching purification process what problems should be paid attention to when the air separation plant restarts after a short-term stop?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top