Why does steelmaking require air separation equipment?
2025.06.30
  Since 1956 China began to have an air separation equipment manufacturing industry, and constantly meet the growing demand for industrial gases from all walks of life, in view of the then poor technology and manufacturing capacity of gas separation equipment manufacturing products, many departments rely on imported equipment to develop the national economy, in the 1950s and 1960s China mainly imported ...
2025.06.27
The leakage of unit or pipeline in the cold box needs removal of perlite treatment. Since it is uncertain whether there is a leakage point in the cold box, it will have a certain impact on removal of perlite. No matter whether the leakage is liquid or air, the sand filling holes at the top should be opened first, so that the residual gas in the cold box can be slowly discharged into the atmosphere. The oxygen content of the gas in the cold box and the pressure indication in the cold box should be strictly monitored in removal of perlite process. In the process of sand stripping, it is particularly important to avoid the formation of sand free area in the middle of the cold box, so as to avoid sand storm caused by the sudden drop of pearlite sand.
2025.06.26
What is the function of the air compression system in air separation equipment?
2025.06.25
The lower the upper tower pressure, the more conducive to the separation of oxygen and nitrogen, and for the full low pressure air separation unit, the lower tower pressure will also be lowered as the upper tower pressure is reduced, and the lower tower pressure can reduce energy consumption. The pressure at the top of the upper tower depends on the resistance of the nitrogen piping in the heat exchange equipment and the resis...
2025.06.24
What are the core functions and structures of the air cooling tower in air separation equipment?
2025.06.23
Influencing factors of cooling effect of nitrogen water tower precooler
2025.06.20
capacity The following precautions should be taken in the operation of a pressurised expander: do not allow the interlock to be removed to start the expander under any circumstances. control the inlet temperature of the expander to be no lower than -118°C. It is not permitted to start the expander with the booster bypass valve FCV401 closed, and the expander should be pre-cooled befor...
2025.06.19
If you experience problems with your air separation device, you can also contact us via live chat or email.
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top