Influencing factors of cooling effect of nitrogen water tower precooler
2025.06.20
capacity The following precautions should be taken in the operation of a pressurised expander: do not allow the interlock to be removed to start the expander under any circumstances. control the inlet temperature of the expander to be no lower than -118°C. It is not permitted to start the expander with the booster bypass valve FCV401 closed, and the expander should be pre-cooled befor...
2025.06.19
According to the dye composition of penetrant, it can be divided into fluorescent penetrant testing, dye penetrant testing and fluorescent dye penetrant testing, which are represented by I, II and Ш respectively. According to the penetrant removal method, it can be divided into water washing type penetrant testing, lipophilic post emulsifying penetrant testing, solvent removing penetrant testing and hydrophilic post emulsifying penetrant testing, which are represented by A, B, C and D respectively; according to the type of imaging agent, it is divided into dry type Powder imaging agent, water soluble imaging agent, water suspension imaging agent, solvent suspension imaging agent and self imaging were expressed as a, b, c, d, e, respectively. II Cd means solvent removal dye penetrant testing, and the imaging agent is solvent suspension type.
2025.06.18
What is the working principle of condensing evaporator for air separation equipment?
2025.06.17
With a certain amount of adsorbent, the height of the adsorbent must not be less than the length of the adsorption zone. This is because when the adsorbent bed height is lower than the length of the adsorption zone, the adsorber will be switched on and the adsorption capacity will be small or even zero. At this point it is necessary to reduce the adsorption cross section and increase the bed height to increase the adsorption capacity. But...
2025.06.16
According to a DEAR air separation user, during the operation of a set of air separation plant that has been in operation for 5 years, it is found that under the condition that the inlet guide vane does not change, the expansion air volume of the expander gradually decreases, and the rotation speed of the expander gradually decreases, the outlet pressure of the booster end of the expander rises from 0.76MPa to 0.8MPa, the inlet temperature rises from - 110 ° C to - 95 ° C, and the working condition of the chilled water pump is poor.
2025.06.13
What are the principles and functions of the refrigeration system in air separation equipment?
2025.06.12
  Liquefied natural gas (LNG) contains a large amount of high-grade cold energy, which has a high economic value. With the current rapid growth of LNG users in China and the intensification of global energy supply constraints, the rational use of LNG cold energy is particularly important for energy conservation.   As China's demand for LNG increases, more LNG receiving stations will be built in coastal areas, where LNG will be...
2025.06.11
If you experience problems with your air separation device, you can also contact us via live chat or email.
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top