What are the structural forms and types of heat exchanger in air separation unit

What are the structural forms and types of heat exchanger in air separation unit
Aug 07, 2025
Author: DEAR AST
Question Reply

In order to reduce the air temperature in the low temperature air separation unit, various heat exchange equipment are needed for cold and heat exchange in various air separation systems, such as nitrogen water precooler, switching heat exchanger, main heat exchanger, condensing evaporator, subcooler, liquefier, vaporizer, electric heater, etc. These heat exchange equipments are installed in each system of the air separation unit, which are necessary for air liquefaction and gas separation.

 

According to the principle of heat transfer, the heat exchanger of air separation unit can be divided into three types:

 

1.Dividingwall type: the cold and hot fluid is separated by the heat transfer wall, the medium does not directly contact in the heat transfer process, and the hot fluid transfers heat to the cold fluid through the heat transfer wall. For example, tube heat exchanger and plate heat exchanger.

 

2.Heat storage type: the cold and hot fluid alternately flows through the solid heat storage body with sufficient heat capacity. The heat storage body absorbs heat through the superheated fluid. When the cold fluid passes through, the heat storage body releases heat, so as to realize the heat exchange of cold and hot fluid. For example, an accumulator.

 

3.Mixed type: the heat transfer of cold and hot fluids is realized in the process of direct mixing and contact between the two fluids, such as nitrogen water precooler, etc.

DEAR Air Separation Solve YourWhat are the structural forms and types of heat exchanger in air separation unitYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts