Why doesn't the full low pressure oxygen generator enter air when it starts?

Why doesn't the full low pressure oxygen generator enter air when it starts?
Apr 11, 2013
Author: DEAR AST
At the beginning of starting the full low pressure oxygen generator, all the air entering the equipment is inflated through the expander, while the total expansion volume of the expander (including the standby) set by the equipment is much smaller than that of the air compressor. In addition, at the beginning, the intake temperature of the expansion machine is much higher than the design value, and the actual air volume that can enter the expansion machine is less than the design expansion volume. Therefore, there must be a part of air to be emptied first, in order to avoid the air compressor overpressure or surge.
When the liquid begins to accumulate, air is sent to the lower tower, then through the throttle throttle to the upper tower, and then combined with the expansion gas to the heat exchanger to recover the cooling. However, at the beginning, the air that can be eaten in the air separation tower is very small, because the liquid air, liquid nitrogen pipeline and regulating valve are considered according to the amount of liquid flowing through, and the specific volume of gas is much larger than that of liquid, therefore, the ability to pass through gas is limited.
With the accumulation of liquid, when the liquid appears in the main cooling, the condensing evaporator starts to work, and the rising steam of the lower tower
Part of it will condense into liquid in the main cold. The pressure of the lower tower decreases due to the condensation of a part of gas, which makes more air "absorb
Enter ". Therefore, with the rise of the main cooling liquid surface, the amount of condensate liquid in the lower tower increases, and the air volume in the tower also increases gradually. Should be--
Close the small air vent valve gradually to let all the air enter the tower.
If the liquid oxygen level has reached the normal height while the air still cannot be eaten in, this is an abnormal working condition. If the main cooling has the accumulation of neon and helium; or the valve opening of liquid nitrogen returning to the tower is too small, which makes the liquid nitrogen liquid level too high, it will cause the actual heat transfer surface of the main cooling is insufficient, both of them will reduce the condensation and the air cannot enter the tower completely. At this time, according to the specific situation, take specific measures such as blowing off neon gas and helium gas or opening the valve of liquid nitrogen returning to the tower.

DEAR Air Separation provides you withWhy doesn't the full low pressure oxygen generator enter air when it starts?, so you can fully understand the latest developments of DEAR Air Separation and the interpretation of DEAR News.
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top