How to maintain the operation and maintenance intercooler box of air separation equipment?

How to maintain the operation and maintenance intercooler box of air separation equipment?
Jan 26, 2026
Author: DEAR AST

In the operation and maintenance of air separation equipment, the maintenance of cold box is very important, which is related to the stable and efficient operation of equipment.
Daily inspection is the basis. The operation and maintenance personnel shall regularly check the appearance of the cold box and check whether there are deformation, cracks and other abnormalities to prevent leakage due to structural damage. Meanwhile, pay attention to whether the foundation of the cold box sinks, so as to avoid the overall operation of the equipment due to unstable foundation. Pay attention to the instruments on the cold box to ensure that the pressure, temperature and other parameters are displayed normally. In case of any deviation, find out the cause in time.
Sealing inspection shall not be ignored. The sealing performance of the cold box directly affects its insulation effect. Regularly check whether the sealing strip is aged or damaged. Timely replace the sealing materials for the parts with problems to prevent external air infiltration, resulting in loss of cooling capacity and increase energy consumption.
Pearlite filling inside the cold box also needs attention. Pearlescent sand plays a good role in thermal insulation. In case of settlement and caking, the thermal insulation performance will be reduced. The filling density and uniformity of perlite shall be inspected regularly, and supplement or replace it if necessary.
In addition, when the equipment is shut down for maintenance, the inside of the cold box shall be thoroughly cleaned to remove impurities and dirt, check the internal pipes and equipment for corrosion and wear, repair or replace the damaged parts in time to prepare for the next startup operation and ensure the long-term stable operation of the air separation equipment.

DEAR Air Separation Solve YourHow to maintain the operation and maintenance intercooler box of air separation equipment?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top