How can I tell if the moisture and carbon dioxide levels in the air after exiting the molecular sieve purifier are excessive and what causes them?

How can I tell if the moisture and carbon dioxide levels in the air after exiting the molecular sieve purifier are excessive and what causes them?
Jun 26, 2024
Author: DEAR AST

Out of the molecular sieve purifier after the air moisture and carbon dioxide content exceeds the standard judgement, usually the following methods:
1)The indication value of the moisture and carbon dioxide detection meter located after the molecular sieve adsorber rises quickly at the end of the cycle and reaches the alarm value quickly;
2) There is freezing of moisture and carbon dioxide in the main heat exchanger. The temperature difference at the hot end increased significantly, and the air separation unit was not cool enough, requiring an increase in the amount of expansion air. Pay special attention to this situation when the moisture and carbon dioxide detection instruments are out of order.
There may be the following reasons for this situation:
1)The molecular sieve has been used for a long time, and the adsorption performance has decreased;
2)Incomplete regeneration of molecular sieve, or steam regeneration heater leakage, regeneration gas moisture; or molecular sieve adsorption of moisture load is too large, affecting the adsorption of carbon dioxide;
3) For horizontal molecular sieve adsorber, due to airflow pulsation and other reasons caused by the bed undulation, short-circuit airflow;
4) For vertical molecular sieve adsorber, short-circuiting of airflow is caused by gaps in the adsorption bed.

DEAR Air Separation Solve YourHow can I tell if the moisture and carbon dioxide levels in the air after exiting the molecular sieve purifier are excessive and what causes them?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
With the rapid growth of liquid air separation plant production and sales, and the global energy crunch, the prospects for the use of liquid air separation plant cold energy are very broad. The use of liquid air separation plant cold energy should be developed in the direction of integration, fully integrated and effective use of liquid air separation plant cold energy liquid air separation units, using circulating nitrogen through the heat exchanger to recycle liquid air separation plant cold, ...
2026.05.13
When the amount of processing air is reduced, the rising steam and reflux liquid in the upper column will be reduced, but the reflux ratio will not change. Therefore, the reduction of processing air in a small range will not affect the purity of oxygen and nitrogen, and the reduction of processing air volume will help to reduce the pressure of the upper and lower columns. However, according to the material balance, the production of oxygen and nitrogen will naturally decrease when the amount of processing air is reduced. If the amount of processing air is too small, there will be leakage on the tray. If the heat and mass exchange of the leaked liquid is not sufficient, the purity of oxygen and nitrogen will be greatly affected, and even the normal production can not be realized. Therefore, the minimum allowable load of distillation column is generally specified.
2026.05.12
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top