What measures to take when the precooling system fails

What measures to take when the precooling system fails
Jun 27, 2024
Author: DEAR AST

In the precooling system of air separation unit, the working temperature should be in specific range, the molecular sieve can work normally. When it is beyond the range of 8-15°, the load will increase, the adsorption effect will reduce and even the adsorption effect lose .

 

If the precooling system fails, air enters the adsorber of molecular sieve, the working temperature is beyond the normal range, the saturated water content in the air increases, and it operates according to the original set adsorption cycle. In the later stage of the adsorption period, a large amount of carbon dioxide will not be removed, and it will be brought into the main heat exchanger and distillation column, which will block the main heat exchanger and liquefizer, and the resistance of the distillation column will be blocked up. In case of serious, it must stop running and re warm up. The argon production will be stopped immediately once the refrigerator stops running with the device of hydrogenation to produce argon.

 

Therefore, when the air separation unit precooling unit fails, some measures are taken to keep the air separation unit in operation in a short period, (1) reduce the air volume appropriately to reduce the load of the adsorber; (2) shorten the adsorption period to ensure the work within the allowable range of adsorption capacity; (3) pay attention to monitoring the carbon dioxide content in the air at the outlet of the adsorber below 1 *10-6. (4) The nitrogen flow rate of the product shall be reduced properly, and the nitrogen flow of the decontamination nitrogen cooling column shall be increased to reduce the temperature of the cooling water as much as possible, and the flow rate of the common cooling water shall be increased.

DEAR Air Separation Solve YourWhat measures to take when the precooling system failsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top