What measures to take when the precooling system fails

What measures to take when the precooling system fails
Jun 27, 2024
Author: DEAR AST

In the precooling system of air separation unit, the working temperature should be in specific range, the molecular sieve can work normally. When it is beyond the range of 8-15°, the load will increase, the adsorption effect will reduce and even the adsorption effect lose .

 

If the precooling system fails, air enters the adsorber of molecular sieve, the working temperature is beyond the normal range, the saturated water content in the air increases, and it operates according to the original set adsorption cycle. In the later stage of the adsorption period, a large amount of carbon dioxide will not be removed, and it will be brought into the main heat exchanger and distillation column, which will block the main heat exchanger and liquefizer, and the resistance of the distillation column will be blocked up. In case of serious, it must stop running and re warm up. The argon production will be stopped immediately once the refrigerator stops running with the device of hydrogenation to produce argon.

 

Therefore, when the air separation unit precooling unit fails, some measures are taken to keep the air separation unit in operation in a short period, (1) reduce the air volume appropriately to reduce the load of the adsorber; (2) shorten the adsorption period to ensure the work within the allowable range of adsorption capacity; (3) pay attention to monitoring the carbon dioxide content in the air at the outlet of the adsorber below 1 *10-6. (4) The nitrogen flow rate of the product shall be reduced properly, and the nitrogen flow of the decontamination nitrogen cooling column shall be increased to reduce the temperature of the cooling water as much as possible, and the flow rate of the common cooling water shall be increased.

DEAR Air Separation Solve YourWhat measures to take when the precooling system failsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top