What measures to take when the precooling system fails

What measures to take when the precooling system fails
Jun 27, 2024
Author: DEAR AST

In the precooling system of air separation unit, the working temperature should be in specific range, the molecular sieve can work normally. When it is beyond the range of 8-15°, the load will increase, the adsorption effect will reduce and even the adsorption effect lose .

 

If the precooling system fails, air enters the adsorber of molecular sieve, the working temperature is beyond the normal range, the saturated water content in the air increases, and it operates according to the original set adsorption cycle. In the later stage of the adsorption period, a large amount of carbon dioxide will not be removed, and it will be brought into the main heat exchanger and distillation column, which will block the main heat exchanger and liquefizer, and the resistance of the distillation column will be blocked up. In case of serious, it must stop running and re warm up. The argon production will be stopped immediately once the refrigerator stops running with the device of hydrogenation to produce argon.

 

Therefore, when the air separation unit precooling unit fails, some measures are taken to keep the air separation unit in operation in a short period, (1) reduce the air volume appropriately to reduce the load of the adsorber; (2) shorten the adsorption period to ensure the work within the allowable range of adsorption capacity; (3) pay attention to monitoring the carbon dioxide content in the air at the outlet of the adsorber below 1 *10-6. (4) The nitrogen flow rate of the product shall be reduced properly, and the nitrogen flow of the decontamination nitrogen cooling column shall be increased to reduce the temperature of the cooling water as much as possible, and the flow rate of the common cooling water shall be increased.

DEAR Air Separation Solve YourWhat measures to take when the precooling system failsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top