What are the reasons why the main cooling liquid level of the air separation equipment is not high and how to solve it?

What are the reasons why the main cooling liquid level of the air separation equipment is not high and how to solve it?
Apr 25, 2024
Author: DEAR AST

What are the reasons why the main cooling liquid level of the air separation equipment is not high and how to solve it?
There are several reasons why the main cooling liquid level is not high:
1. The incomplete heat exchange loss of the main heat exchanger increases;
2. The expansion machine has a small temperature difference, low efficiency, and less expansion;
3. The temperature of the air entering the main heat exchanger is high;
4. Equipment leakage increases the loss of cold running;
5. A large amount of liquid products are taken out.
The solution is as follows:
1. Reasonably allocate cooling capacity, and if the heat exchanger is blocked, it should be fully heated and blown out;
2. Check the expander and handle it;
3. Check the air cooling system and molecular sieve adsorber and handle them;
4. Inspect cold insulation materials, detect leaks, and handle them;
5. Reduce the amount of liquid extracted.
DEAR Air Separation specializes in the research and development, manufacturing, and installation of various complete sets of air separation equipment, providing customers with efficient engineering and technical solutions.

DEAR Air Separation Solve YourWhat are the reasons why the main cooling liquid level of the air separation equipment is not high and how to solve it?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top