What are the roles and principles of pre-cooling systems for air separation equipment?

What are the roles and principles of pre-cooling systems for air separation equipment?
Feb 01, 2024
Author: DEAR AST

The main function of the pre-cooling system is to cool the wet air after pressurisation of the air compressor, and further wash the micro-particles of dust, part of the water-soluble substances (NH3, SO2, etc.) and other impurities in the air. The air cooled by the air-cooled tower air approximate saturated wet air, according to the working characteristics of the purification system, wet air out of the air-cooled tower, the lower the temperature of the water content is lower, and the more conducive to reducing the adsorption load of the purification system.
Working principle and process: the air-cooled tower is divided into two sections, the lower section of the cooling water with circulating water, the upper section of the cooling water with chilled water, the direct use of cooling water and chilled water in the bulk packing and wet air contact heat transfer to reduce the temperature of the wet air. Cooling water is introduced from the lower part of the air cooling tower and chilled water from the upper part of the air cooling tower. The cooling water comes from the pool of the cooling water supply pipe network of the plant, and is introduced after being pressurised by the cooling water pump, and then collected at the bottom of the air-cooling tower after heat exchange and returned to the cooling water return pipe network. The chilled water comes from the circulating pool, and contacts with dry dirty nitrogen in the water-cooled tower, using the latent heat of vaporisation of water to achieve cooling, and then further reduces the temperature by the ammonia freezer, and then is introduced under pressure by the chilled water pump. At the top of the air cooling tower, there is a water collector, which can separate the free water entrained in the air.

DEAR Air Separation Solve YourWhat are the roles and principles of pre-cooling systems for air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top