What are the roles and principles of pre-cooling systems for air separation equipment?

What are the roles and principles of pre-cooling systems for air separation equipment?
Feb 01, 2024
Author: DEAR AST

The main function of the pre-cooling system is to cool the wet air after pressurisation of the air compressor, and further wash the micro-particles of dust, part of the water-soluble substances (NH3, SO2, etc.) and other impurities in the air. The air cooled by the air-cooled tower air approximate saturated wet air, according to the working characteristics of the purification system, wet air out of the air-cooled tower, the lower the temperature of the water content is lower, and the more conducive to reducing the adsorption load of the purification system.
Working principle and process: the air-cooled tower is divided into two sections, the lower section of the cooling water with circulating water, the upper section of the cooling water with chilled water, the direct use of cooling water and chilled water in the bulk packing and wet air contact heat transfer to reduce the temperature of the wet air. Cooling water is introduced from the lower part of the air cooling tower and chilled water from the upper part of the air cooling tower. The cooling water comes from the pool of the cooling water supply pipe network of the plant, and is introduced after being pressurised by the cooling water pump, and then collected at the bottom of the air-cooling tower after heat exchange and returned to the cooling water return pipe network. The chilled water comes from the circulating pool, and contacts with dry dirty nitrogen in the water-cooled tower, using the latent heat of vaporisation of water to achieve cooling, and then further reduces the temperature by the ammonia freezer, and then is introduced under pressure by the chilled water pump. At the top of the air cooling tower, there is a water collector, which can separate the free water entrained in the air.

DEAR Air Separation Solve YourWhat are the roles and principles of pre-cooling systems for air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top