Why is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?

Why is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?
Jan 22, 2024
Author: DEAR AST

Air separation plant in the start-up phase before the emergence of liquid, the lowest temperature is generated by the expander, the temperature in the distillation tower can not be lower than the temperature after expansion.
But when the lower tower appears liquid, saturated liquid section of the subcooling flow to the upper tower, the pressure is reduced, part of the gasification, the temperature also fell to the upper tower pressure corresponding to the saturation temperature. In addition, the bottom of the tower on the liquid oxygen temperature (-1800C) or so in the gasification process, and the liquid on the tower plate heat, mass exchange, nitrogen component evaporation, gas temperature reduction, to be the gas through a number of sections to reach the top of the tower when the gas has reached the pure nitrogen, the temperature has fallen to the temperature with the liquid temperature at the same place (-193 ° C). Therefore, the formation of the lowest temperature in the tower is the result of liquid throttling expansion and gas-liquid heat and mass exchange.
DEAR Air Separation is a professional R & D, manufacturing, installation of various types of complete sets of air separation equipment manufacturers, to provide customers with high quality air separation projects, to provide customers with complete and efficient engineering solutions to meet customer needs.

DEAR Air Separation Solve YourWhy is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
How to maintain the operation and maintenance intercooler box of air separation equipment?
2026.01.26
The amount of liquid nitrogen removed from the lower column of the air separation unit will affect the purity of the liquid nitrogen in the lower column and the oxygen enriched liquid air at the bottom of the column. When the liquid nitrogen removal amount of the lower column increases, the reflux liquid participating in the heat and mass exchange of the lower column will be reduced, the temperature rise of the rising steam on the column plate will be correspondingly reduced, the condensation of the rising steam will not be sufficient, the oxygen component will be condensed less, the purity of nitrogen at the column top will be reduced, and the purity of liquid nitrogen will be naturally reduced. At the same time, the temperature rise of the downflow liquid will increase, the liquid evaporation will be more sufficient, more nitrogen components will be evaporated to the top of the column, and the purity of the liquid air at the bottom of the column will be improved accordingly.
2026.01.23
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top