Why is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?

Why is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?
Jan 22, 2024
Author: DEAR AST

Air separation plant in the start-up phase before the emergence of liquid, the lowest temperature is generated by the expander, the temperature in the distillation tower can not be lower than the temperature after expansion.
But when the lower tower appears liquid, saturated liquid section of the subcooling flow to the upper tower, the pressure is reduced, part of the gasification, the temperature also fell to the upper tower pressure corresponding to the saturation temperature. In addition, the bottom of the tower on the liquid oxygen temperature (-1800C) or so in the gasification process, and the liquid on the tower plate heat, mass exchange, nitrogen component evaporation, gas temperature reduction, to be the gas through a number of sections to reach the top of the tower when the gas has reached the pure nitrogen, the temperature has fallen to the temperature with the liquid temperature at the same place (-193 ° C). Therefore, the formation of the lowest temperature in the tower is the result of liquid throttling expansion and gas-liquid heat and mass exchange.
DEAR Air Separation is a professional R & D, manufacturing, installation of various types of complete sets of air separation equipment manufacturers, to provide customers with high quality air separation projects, to provide customers with complete and efficient engineering solutions to meet customer needs.

DEAR Air Separation Solve YourWhy is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top