Why is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?

Why is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?
Jan 22, 2024
Author: DEAR AST

Air separation plant in the start-up phase before the emergence of liquid, the lowest temperature is generated by the expander, the temperature in the distillation tower can not be lower than the temperature after expansion.
But when the lower tower appears liquid, saturated liquid section of the subcooling flow to the upper tower, the pressure is reduced, part of the gasification, the temperature also fell to the upper tower pressure corresponding to the saturation temperature. In addition, the bottom of the tower on the liquid oxygen temperature (-1800C) or so in the gasification process, and the liquid on the tower plate heat, mass exchange, nitrogen component evaporation, gas temperature reduction, to be the gas through a number of sections to reach the top of the tower when the gas has reached the pure nitrogen, the temperature has fallen to the temperature with the liquid temperature at the same place (-193 ° C). Therefore, the formation of the lowest temperature in the tower is the result of liquid throttling expansion and gas-liquid heat and mass exchange.
DEAR Air Separation is a professional R & D, manufacturing, installation of various types of complete sets of air separation equipment manufacturers, to provide customers with high quality air separation projects, to provide customers with complete and efficient engineering solutions to meet customer needs.

DEAR Air Separation Solve YourWhy is the minimum temperature in the air separation tower of an air separation plant lower than the expander outlet temperature?You can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What precautions should be taken when designing a complete set of air separation equipment?
2024.11.22
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top