Why does the moisture content of air decrease after passing through the cooling tower of an air separation plant

Why does the moisture content of air decrease after passing through the cooling tower of an air separation plant
Nov 02, 2023
Author: DEAR AST

For low-pressure air separation devices, the absolute pressure of compressed air discharged from the air compressor is around 0.6MPa. After compression, the moisture content per unit volume of air increases, causing its moisture content to reach the saturation level corresponding to the temperature at that time. When air flows through the air cooling tower, as the temperature decreases, the corresponding saturated moisture content decreases, and the excess part will precipitate from the gas in a liquid state. This portion of water vapor condenses into water, while releasing latent heat of condensation, which not only increases the cooling water volume but also increases the water temperature. But the temperature of the air exiting the tower decreases, so although the air comes into direct contact with water in the cooling tower, its moisture content will actually decrease.

For example, for a 3200m3/h oxygen generator, the processing air volume is 19580m3/h, and the absolute pressure of compressed air is 0.59MPa. The temperature of the air entering the air cooling tower is 50 ℃, and the temperature of the air exiting the air cooling tower is 30 ℃. In this case, the amount of water released by the air passing through the cooling tower can reach 220kg/h.

Kaifeng DEAR Air Separation is deeply rooted and practiced in the field of air separation research. It specializes in the research and development, manufacturing, and installation of various complete sets of air separation equipment, and is good at providing customers with the most competitive air separation project design solutions. It has been recognized and trusted by a large number of customers!

DEAR Air Separation Solve YourWhy does the moisture content of air decrease after passing through the cooling tower of an air separation plantYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What precautions should be taken when designing a complete set of air separation equipment?
2024.11.22
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top