Why does the moisture content of air decrease after passing through the cooling tower of an air separation plant

Why does the moisture content of air decrease after passing through the cooling tower of an air separation plant
Nov 02, 2023
Author: DEAR AST

For low-pressure air separation devices, the absolute pressure of compressed air discharged from the air compressor is around 0.6MPa. After compression, the moisture content per unit volume of air increases, causing its moisture content to reach the saturation level corresponding to the temperature at that time. When air flows through the air cooling tower, as the temperature decreases, the corresponding saturated moisture content decreases, and the excess part will precipitate from the gas in a liquid state. This portion of water vapor condenses into water, while releasing latent heat of condensation, which not only increases the cooling water volume but also increases the water temperature. But the temperature of the air exiting the tower decreases, so although the air comes into direct contact with water in the cooling tower, its moisture content will actually decrease.

For example, for a 3200m3/h oxygen generator, the processing air volume is 19580m3/h, and the absolute pressure of compressed air is 0.59MPa. The temperature of the air entering the air cooling tower is 50 ℃, and the temperature of the air exiting the air cooling tower is 30 ℃. In this case, the amount of water released by the air passing through the cooling tower can reach 220kg/h.

Kaifeng DEAR Air Separation is deeply rooted and practiced in the field of air separation research. It specializes in the research and development, manufacturing, and installation of various complete sets of air separation equipment, and is good at providing customers with the most competitive air separation project design solutions. It has been recognized and trusted by a large number of customers!

DEAR Air Separation Solve YourWhy does the moisture content of air decrease after passing through the cooling tower of an air separation plantYou can also learn about otherBiogas purification FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top