Function of air receiver in oxygen supply system

Function of air receiver in oxygen supply system
Nov 25, 2022
Author: DEAR AST

The oxygen production of the oxygen generator is continuous and stable, and the oxygen consumption of nitrogen and oxygen users is generally fluctuating. For example, in steel production, the converter only needs a lot of oxygen in the blowing period in each steelmaking cycle, and does not need oxygen in other times. Therefore, it is necessary to set up an intermediate gas tank. When oxygen is not used or the oxygen consumption is less than the output of the oxygen generator, the excess oxygen can be stored in the gas tank. When the oxygen consumption is greater than the output of the oxygen generator, the stored oxygen can be released. The pressure of the tank shall be greater than the pressure required by the user.

During the design and manufacturing of the 30000 grade air separation equipment KDONAr-30000/70000/900 with argon supplied by Kaifeng DEAR Air Separation Industry Co., Ltd. to Hebei Anfeng Iron and Steel Co., Ltd, Thus, the support angle of the first support roller and the second support roller can be adjusted to fit with the surface of the roller, so as to achieve the effect of stabilizing the support roller. Convenient adjustment, wider angle range, stable and reliable.

DEAR Air Separation Solve YourFunction of air receiver in oxygen supply systemYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Brief description of the molecular sieve problem The purifier CO₂ suddenly started to run abnormally and suddenly went out of range in liquid air separation plants, the dew point never changed significantly. The dew point did not change significantly. In order to ensure that the other molecular sieve had enough time to regenerate, the time could not be shortened any further. At this point there was a relatively stable situation with no further deterioration. Check the trend graph for a cold bl...
2026.09.21
The most important index of radiographic quality is the sensitivity of radiography, which is the size of the smallest defect along the direction of ray penetration that can be found on the negative plate quantitatively. Natural defects’ size are hard to be sure. It is obvious that it is unrealistic to use natural defects to evaluate the sensitivity of radiography. Therefore, in order to facilitate the evaluation of photographic quality, it is often used to monitor the image quali...
2026.09.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top