Tandem water cooling system of piston compressor

Tandem water cooling system of piston compressor
Nov 24, 2022
Author: DEAR AST

The cooling system of piston compressor includes cylinder cooling, interstage cooling and post cooling of final exhaust. There are two types of cooling: water cooling and air cooling. Water cooling is generally adopted for air separation plant. The cooling water first enters the intercooler, then the first stage cylinder water jacket, then the second stage cylinder water jacket, and finally the aftercooler. This water cooling system is called series type, which has the advantage of simple structure, but is not suitable for multi-stage compression. The more stages, the worse the cooling effect.

The efficient sales team is the driving force for the development of DEAR Air. If an enterprise does not have an excellent sales team, its sales plan and sales target formulated according to its development direction will be like a castle in the air and difficult to achieve. In recent years, in the process of continuous growth of the enterprise, Deer Air Separation has built a sales team with high team combat effectiveness and cohesion, which has provided full guarantee for the enterprise operation, won many battles in the air separation market, and made great contributions to the long-term development of the enterprise.

DEAR Air Separation Solve YourTandem water cooling system of piston compressorYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Sieve tray is one of the most widely used trays in air separation columns. Its main structure is that there are evenly distributed small holes with spacing of 2.1 ~ 3.25 mm and diameter of 0.8 ~ 0.13 mm on the tray. During the operation, the steam bubbling up through the liquid layer through the sieve hole, and the liquid on the tray can only flow in a fixed direction because it is held by the steam. The advantages of sieve tray column are simple manufacture and high efficiency. The disadvantages are that liquid may leak through the sieve hole when the load is too low.
2026.11.03
What is the Air separation unit instrument cluster and what is the relationship between transmitters, display tables, regulators, and membrane control valves?Air separation unit.1 g potassium dichromate or 2 g sodium nitrite can be added to each liter of water (not suitable for nonferrous metal degreasing); due to the toxicity or explosion of degreasing agent, attention must be paid to prevent poisoning and formation of explosive mixture. In alkaline cleaning, the pipeline with more oil stains is heated to 60-90 ℃ with 10% sodium hydroxide solution, then neutralized with 15% nitric acid and washed with clean water.Air separation unit.From the vaporization temperature (saturation temperature) of liquid oxygen, if the liquid oxygen surface is too high, the greater the static pressure difference between the upper and lower liquid oxygen surface, the higher the average pressure of liquid oxygen and the corresponding saturation temperature. In order to maintain the heat transfer temperature
2026.11.02
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top