What are the steps for the naked cooling of the cooling fractionator system of the air separation unit

What are the steps for the naked cooling of the cooling fractionator system of the air separation unit
Oct 24, 2024
Author: DEAR AST

Conditions required before cooling: equipment and pipelines have been thoroughly heated and purged; The air filter is put into normal operation; Put the air turbine compressor into normal operation; The air precooling system is put into normal operation; The molecular sieve purification system is put into normal operation; The booster compressor unit is put into operation; The instrument control and electric control systems are put into normal operation.

Liquid accumulation: the initially accumulated liquid on the liquid oxygen side of the main cooling should be drained. Adjust the upper tower pressure to accelerate the accumulation of main cooling liquid. When the liquid level of liquid air reaches the normal value, send the liquid air to the upper tower. At this stage, the amount of air entering the tower will continue to increase. Therefore, pay attention to the discharge pressure of the air compressor and adjust the pressure of the upper and lower towers to be within the specified value.

Establishment of distillation process: when the resistance value of the upper and lower towers reaches about 50% of the design value, it can be considered that the distillation conditions of the upper and lower towers have been established, and the resistance of the upper and lower towers can be controlled by adjusting the set value of the valve.

Purity adjustment: according to the data of each analysis point of the analyzer, use the valve to adjust the distillation conditions of the upper and lower towers. According to the purity of oxygen and nitrogen of the product, gradually increase the product output until the normal value.

When the product index reaches the design value, the product can be switched from the vent pipeline to the product output pipeline, and the working pressure of the upper and lower towers can be adjusted at the same time. After the fractionator works stably, put the automatic control instrument into operation. When the liquid oxygen level of the main cooling liquid rises continuously, the liquid oxygen should be discharged to keep the liquid oxygen level from being too high.

DEAR air separation provides customers with the design scheme of air separation project, and is committed to building a complete set of high-quality air separation equipment with the characteristics of advanced technology, reliable quality and high cost performance.

DEAR Air Separation Solve YourWhat are the steps for the naked cooling of the cooling fractionator system of the air separation unitYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top