当前位置: Home / Faq / Small air separation FAQ /

Physical principle of condensing evaporator

Physical principle of condensing evaporator
Jul 05, 2022
Author: DEAR AST

Generally, the liquefaction temperature of nitrogen is higher than that of oxygen, but the condensing evaporator between the upper and lower towers of the air separation tower can use the condensation of gas and nitrogen to vaporize liquid oxygen. This is because we usually think that the premise that the liquefaction temperature of nitrogen is lower than that of oxygen is under the same pressure, while the pressure at the top of the lower tower is about 0.58mpa, and the pressure at the bottom of the upper tower is generally 0.149ma, Different pressures cause the inversion of oxygen and nitrogen saturation temperature. Using this principle, the condensation evaporator can continuously provide liquid nitrogen as reflux liquid for the lower tower, and provide gas oxygen as rising gas for the upper tower to participate in fractionation.

Ten times hand in hand, win-win future: in the increasingly competitive market economy environment, what kind of charm does an enterprise have that is worth trusting customers? Kaifeng DEAR air separation Industrial Co., Ltd. and Hebei Anfeng iron and Steel Group Co., Ltd. have cooperated for ten times. From the signing of the first set of two-stage distillation low-pressure process kdon-15000/35000 air separation equipment in January 2009 to the successful commissioning of the tenth set of multi-stage distillation hydrogen free argon production KDON (AR) 30000/70000-900 air separation equipment in November 2018, Deere air separation has continued to write the industry legend with its strength for nearly ten years.

DEAR Air Separation Solve YourPhysical principle of condensing evaporatorYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
What is the principle of return slop nitrogen removing frozen water and carbon dioxide?
2026.05.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top