当前位置: Home / Faq / Liquefied air separation FAQ /

Differential pressure transmitters for liquid air separation plants

Differential pressure transmitters for liquid air separation plants
Jun 23, 2022
Author: DEAR AST

There are two types of differential pressure transmitters, electric and pneumatic. Here we only introduce the structure principle of pneumatic differential pressure transmitter, the role of differential pressure transmitter is to convert the differential pressure signal into 0.02 ~ 0.1MPa air pressure signal, for long-distance transmission, and to the display instrument display or record down.
The measured pressure difference P1 and P2 are introduced into the positive and negative pressure chambers respectively. Because P1>P2, the differential pressure Δp=p1-p2, the diaphragm box moves downwards, driving the main lever to produce a counterclockwise moment with the centre of the seal as the fulcrum, so that the baffle at the right end is close to the nozzle, the back pressure of the nozzle increases and the output pressure of the amplifier rises. In order to keep the baffle plate and the nozzle at a stable distance, a portion of the output pressure is sent to the feedback bellows, which generates a clockwise torque on the main lever.
DEAR Air Separation Equipment's differential pressure transmitter production design system ensures high efficiency in small air separation units, large air separation units and liquid air separation plants.

秦皇岛安丰钢铁有限公司KDON(Ar)-1600020000-500型空分设备

DEAR Air Separation Solve YourDifferential pressure transmitters for liquid air separation plantsYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top