Small air separation unit to measure low temperature

Small air separation unit to measure low temperature
Jun 10, 2022
Author: DEAR AST

The resistance value of metal materials are changing with temperature, but to be used to make resistance thermometer, the material has certain requirements:.
1) the need for a high resistance temperature coefficient in the temperature range, that is, when the temperature changes 1 ℃, the change in resistance value is large, can make the sensitivity higher, and the best resistance value of the relationship with the temperature is linear.
2) high chemical stability, easy to purify and replicate.
3) at a certain temperature, the unit length, unit cross-section of the wire resistance value is larger (i.e., larger than the resistance), in order to make the thermometer volume can be smaller.
4) cheap. Practice has proved: suitable for making RTD elements of materials such as platinum, copper, iron, nickel, etc..
Platinum is a more ideal material, it is chemically stable, easy to get high-purity platinum wire, larger than the resistance, high accuracy of temperature measurement, resistance and temperature in the range of -200 ~ 0 ℃ into an approximate linear relationship. Although copper has the advantages of cheap, high resistance temperature coefficient, but the temperature measurement range than platinum is small, generally between -50 ~ 150 ℃, the specific resistance is smaller, large volume, low sensitivity. Although iron, nickel and other high resistance temperature coefficient, but the relationship between resistance and temperature is not linear, and difficult to purify, generally rarely used. Therefore, the measurement of low temperature commonly used platinum resistance thermometer. Compared with thermocouples, it has a higher sensitivity, accuracy at low temperatures, does not require cold-end temperature compensation, easy to transmit far, centralized detection, so in the small air separation unit in the cold box almost all use platinum resistance thermometer.

上海宝冶集团有限公司-7500(2)

DEAR Air Separation Solve YourSmall air separation unit to measure low temperatureYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top