Selection of Thermometers for Large Air Separation Plants

Selection of Thermometers for Large Air Separation Plants
Jun 09, 2022
Author: DEAR AST

Resistance thermometer. It is composed of thermal resistance and its matching display instrument. The thermal resistance element is made of the characteristic that the resistance value of metal (or semiconductor) changes with temperature. Therefore, the change of temperature can be measured by measuring the change of resistance. Platinum thermal resistance (graduation number is Pt100) can be used to measure the temperature in the range of -200 ~ 650 ℃ in industry. In addition to the advantages of thermocouples, it also has the advantages of high measurement accuracy in the low temperature range, so it is more widely used in the low temperature field. It is used for low temperature measurement in the cold storage box in the large air separation plant.
4) Pressure gauge thermometer. It is made by using the principle that the pressure of the gas (or vapor, liquid) in a sealed container changes with temperature. When measuring the temperature, insert the temperature bulb into the measured medium. When the temperature changes, the pressure of the gas (or vapor, liquid) in the temperature bulb changes, and it is transmitted to the elastic pressure gauge through the capillary, and the temperature change can be measured according to the pressure change. It can measure the temperature in the range of -100~600℃. The wTZ-288 electric contact pressure thermometer is commonly used in large air separation equipment. The measuring range is 0~100℃. It is used to measure the lubricating oil temperature.微信图片_20200102093128

DEAR Air Separation Solve YourSelection of Thermometers for Large Air Separation PlantsYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top