The main factors affecting the packing capacity of liquid separation plants

The main factors affecting the packing capacity of liquid separation plants
May 31, 2022
Author: DEAR AST

As far as the liquid holding capacity is concerned, it is easier to establish a distillation condition in a packed column. This is because a packed tower only needs to wet the surface of the dressing and the liquid film can be built up, whereas a sieve plate tower requires the liquid layer to reach a certain height. The main factors affecting the amount of liquid held in the packed tower include: the shape, size, surface characteristics and filling characteristics of the packing; gas-liquid two-phase flow of the physical characteristics; the structure of the tower components and installation characteristics; the operating conditions of the tower.

10

DEAR Air Separation Solve YourThe main factors affecting the packing capacity of liquid separation plantsYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When the main condenser evaporator leaks seriously, a large amount of high-pressure nitrogen will leak to the low-pressure oxygen side, and the pressure of the upper and lower columns and the purity of the product will change significantly until normal production cannot be maintained. When the main condenser evaporator leaks slightly, the pressure of the upper and lower columns will not change significantly, and the purity of liquid oxygen in the main condenser evaporator will not decrease significantly. The common phenomenon is that the purity of the gas and liquid oxygen in the main condensing evaporator is very different, and the gas concentration is lower than that in equilibrium with liquid oxygen. For example, the concentration of liquid oxygen is 99% and that of gaseous oxygen is 96%, that 7 main cooling pipes were found to be leaking during maintenance. The common causes of leakage are as follows: 1. Pipes are worn due to mutual vibration. For long tube condensing evap
2025.11.25
How to prevent scaling of cooling system of air separation equipment?
2025.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top