What measures to consider for the transport and acceptance of oxygen piping materials in small air separation units?

What measures to consider for the transport and acceptance of oxygen piping materials in small air separation units?
Apr 19, 2022
Author: DEAR AST

Small air separation unit material production process should reduce grease and debris pollution and reduce the amount of subsequent processing works and processing difficulties. Small air separation unit material section in the factory before, transport and storage process using the adoption of strict closed measures to prevent secondary pollution. Specific measures are: Store small parts in pockets: Close the openings of the small air separation unit : Nitrogen sealing or drying and other methods to protect carbon steel small air separation unit oxygen piping storage and transport process, shall not be in contact with non-alloy steel, low-alloy steel piping components to prevent stainless steel piping carburization.

Oxygen piping material acceptance: oxygen piping components (pipes, valves, fittings, flanges, etc.) should comply with the relevant requirements of the design provisions and specifications, must have quality certification documents, no quality certification documents of the product shall not be used. Before the product is used, the quality certification document should be reviewed and checked with the physical object. The construction procedures of bevel grinding, undercutting grouping and welding of pipes are carried out according to the original welding scheme of the coal gasification project. Oxygen pipeline prefabrication is non-destructively tested at 100% RT flaw detection. The opening and welding of the instrumentation taking source components on the pipeline shall be carried out prior to the installation of the pipeline.

The characteristics of oxygen piping for small air separation unit determine its high quality requirements, therefore the oxygen piping manufactured by Dear Air Separation is strictly implemented in every step of the process and technical measures to ensure the safe and stable operation of the small air separation units, large air separation units and liquid air separation plants.山东钢铁集团(壶井)16000

DEAR Air Separation Solve YourWhat measures to consider for the transport and acceptance of oxygen piping materials in small air separation units?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top