当前位置: Home / Faq / Small air separation FAQ /

Circulating cooling water system cleaning and pre-filming in small air separation units

Circulating cooling water system cleaning and pre-filming in small air separation units
Apr 12, 2022
Author: DEAR AST

Water circulation, whether it's new or old, requires system cleaning and pre-filming before dosing. The pretreatment of circulating water systems for chemical treatment includes cleaning work and pre-film work. For new systems, small air separation units and piping can sometimes have debris, debris and dust left in the system during installation, and sometimes cooling equipment can be heavily rusted and oiled. If these debris and oil are not cleaned, they will affect the next step of the pre-film treatment. The small air separation unit cooling equipment that has been put into operation also often has scale, slime and metal corrosion products, which can seriously affect the life of the equipment and heat transfer efficiency. Therefore, for new systems, cleaning can improve the pre-film effect and reduce corrosion and scaling. For the old system has been put into operation, cleaning work can improve the heat transfer efficiency, improve the process operating conditions, to ensure a long production cycle, reduce energy consumption and extend the service life of small air separation unit. Therefore, cleaning is an essential part of circulating water system start-up.

Dear Air Separation has 20 years of experience in the manufacture of air separation equipment and nearly 10 years of experience in the operation and maintenance of small air separation units, forming a mature and complete standardised process for the overall operation and maintenance of large air separation units. The industrial gas investment model allows users to have more options for cooperation and brings a higher rate of return for partners.

朱克嘉-凌云(缅甸1500)

DEAR Air Separation Solve YourCirculating cooling water system cleaning and pre-filming in small air separation unitsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top