当前位置: Home / Faq / Large air separation FAQ /

Self-cleaning air filter in large air separation units

Self-cleaning air filter in large air separation units
Mar 30, 2022
Author: DEAR AST

(1) In the box combination installation, the combined part of the clean air chamber should pay attention to.

(2)the use of welding form, must be the net air chamber around the welding of the sealing welding (i.e. full welding), do not allow intermittent welding.

(2)If the combination of gasket in the middle of the chamber is used, the bolts and nuts of the combination should be tightened. and can be sealed by injecting glass glue at the seam of the splice.

(3) When installing the large air separation unit filter box, the nuts at the end of the fixing bracket must be tightened and must not be loosened.

(4) After the installation of large air separation unit box combination, attention should be paid to check whether there is a carved bruise in the installation, if (4) After the installation of large air separation unit box combination, attention should be paid to check whether there are any bruises in the installation, and if so, the primer and top coat should be applied in time.

(5) After installation, use a hoover or other apparatus to thoroughly clean up the debris, welding slag and dust in the gas chamber sink box (or gas collection box).

(6) Check that the maintenance manhole on each level is tightly covered and sealed.

When installing large air separation units, Dear Air Separation checks the control program of the controller in accordance with the requirements of the instruction manual, and check whether the differential pressure controller is connected to the controller, the action of the solenoid valve diaphragm and the signal connection of the DCS system. For areas with many thunderstorms, lightning protection and earthing measures must be installed.

252058689457107136

DEAR Air Separation Solve YourSelf-cleaning air filter in large air separation unitsYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why do molecular sieves in small air separation unit use bunk beds? Molecular sieve purifiers are used in both small and large air separation plants to purify the air. carbon dioxide, acetylene, and various hydrocarbons. Some molecular sieves small air separation unit use a double bed because the adsorption capacity of activated alumina is relatively large for air with high water content, but as the water content of the air decreases, the adsorption capacity decreases rapidly. The molecular s...
2026.01.29
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top