Self-cleaning air filter in large air separation units

Self-cleaning air filter in large air separation units
Mar 30, 2022
Author: DEAR AST

(1) In the box combination installation, the combined part of the clean air chamber should pay attention to.

(2)the use of welding form, must be the net air chamber around the welding of the sealing welding (i.e. full welding), do not allow intermittent welding.

(2)If the combination of gasket in the middle of the chamber is used, the bolts and nuts of the combination should be tightened. and can be sealed by injecting glass glue at the seam of the splice.

(3) When installing the large air separation unit filter box, the nuts at the end of the fixing bracket must be tightened and must not be loosened.

(4) After the installation of large air separation unit box combination, attention should be paid to check whether there is a carved bruise in the installation, if (4) After the installation of large air separation unit box combination, attention should be paid to check whether there are any bruises in the installation, and if so, the primer and top coat should be applied in time.

(5) After installation, use a hoover or other apparatus to thoroughly clean up the debris, welding slag and dust in the gas chamber sink box (or gas collection box).

(6) Check that the maintenance manhole on each level is tightly covered and sealed.

When installing large air separation units, Dear Air Separation checks the control program of the controller in accordance with the requirements of the instruction manual, and check whether the differential pressure controller is connected to the controller, the action of the solenoid valve diaphragm and the signal connection of the DCS system. For areas with many thunderstorms, lightning protection and earthing measures must be installed.

252058689457107136

DEAR Air Separation Solve YourSelf-cleaning air filter in large air separation unitsYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why is the pressure in the lower tower of the air separation equipment higher than that in the upper tower?
2024.04.23
The expansion air volume entering the upper tower increases, and the reflux ratio of the distillation section decreases correspondingly. In order to achieve the required purity of nitrogen products, more tower plates need to be set. When the reflux ratio is reduced to countless Tower plates needed to be set to make the purity of nitrogen reach the required value, then the reflux ratio is called the minimum reflux ratio. The expansion air volume entering the upper tower is first limited by the minimum reflux ratio. The closer the reflux ratio is to the minimum reflux ratio, the faster the number of tower plates needed to ensure the product purity increases, which will lead to the increase of investment, the increase of tower plate resistance, the increase of Operation pressure and the increase of energy consumption. Therefore, the reflux ratio after the inflated air enters the tower should be larger than the minimum reflux ratio. When the purity of nitrogen is required to be low, the...
2024.04.22
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top