当前位置: Home / Faq / Small air separation FAQ /

Small air separation units start-up operation accumulation 

Small air separation units start-up operation accumulation 
Mar 22, 2022
Author: DEAR AST

Liquid accumulation stage essentials: ensure that the two expansion machine pressure before the machine is stable, maintain the highest permissible speed, so that it runs at full load. When the condensing evaporator liquid oxygen liquid surface, should promptly close the small oxygen flow to the normal flow of about 1/3, control the upper tower pressure, and gradually close the small liquid nitrogen throttle valve to full shutdown. Timely adjust the amount of air into the tower, to ensure that the air temperature before entering the lower tower as low as possible, increase the amount of moisture into the tower air. When the liquid level rises to 2/3 of the normal liquid level, slowly open the liquid nitrogen back to the lower tower valve, slightly open the liquid nitrogen throttle valve.

The key to adjusting the pure stage: ensure that the condensing evaporator liquid oxygen level in the normal range, and the state of stability, timely adjustment of the expander. In order to ensure the efficient operation of one expander, the other expander gradually reduce the amount until it stops. Liquid-air throttle valve, liquid nitrogen throttle valve and liquid nitrogen back down the tower valve switch to slow, cut to have foresight. When using the liquid-air throttle valve to control the lower tower liquid-air level, use the liquid-nitrogen throttle valve to control the lower tower liquid-air and liquid-nitrogen purity. According to the oxygen purity gradually open up the oxygen delivery valve to normal value. Adjust the nitrogen outlet valve and dirty nitrogen outlet valve to gradually increase the nitrogen purity to the normal index under the premise of ensuring the stability of the upper tower pressure. When the oxygen and nitrogen product purity reaches the target, adjust the expander air into the upper tower gas volume to increase the product output. Seize the important link of liquid oxygen level stability during normal operation and adjust the amount of cold production in time.

Dear Air has many years of experience in manufacturing small air separation units and large air separation units, focusing on all aspects to ensure the overall stable operation of liquid air separation plants.

缅甸1500空分冷箱

DEAR Air Separation Solve YourSmall air separation units start-up operation accumulation You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant piston compressor clearance volume is: the compressor at the end of the exhaust, the piston and the cylinder end of the wall between the residual part of the high pressure gas occupied by the cylinder volume. The existence of the residual volume directly reduces the exhaust volume of the compressor, at the same time, the suction of this part of the high pressure gas expansion, will also cause a delay in the suction process, the reduction in suction volume, ultimately ...
2026.02.11
All low pressure air separation units are usually equipped with nitrogen water precoolers. It mainly uses the unsaturation of nitrogen in sewage to evaporate part of water. As the water evaporates, it absorbs the latent heat of vaporization to lower the temperature of the cooling water, which is then used to cool the treated air and lower the temperature of the air entering the column. Therefore, it includes air cooling column and water cooling column. The basic purpose of setting up nitrogen precooler is to reduce the air temperature entering the air separation column and avoid the temperature fluctuation greatly. Because the inlet air temperature directly affects the operation conditions of the switching heat ex-changer and distillation column, as well as the economy of the whole air separation unit. In the design, the air temperature entering the column is usually set at 30 ° C. When the inlet temperature of the column is higher than the design index during operation, the throttl
2026.02.10
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top