当前位置: Home / Faq / Small air separation FAQ /

Small air separation units start-up operation accumulation 

Small air separation units start-up operation accumulation 
Mar 22, 2022
Author: DEAR AST

Liquid accumulation stage essentials: ensure that the two expansion machine pressure before the machine is stable, maintain the highest permissible speed, so that it runs at full load. When the condensing evaporator liquid oxygen liquid surface, should promptly close the small oxygen flow to the normal flow of about 1/3, control the upper tower pressure, and gradually close the small liquid nitrogen throttle valve to full shutdown. Timely adjust the amount of air into the tower, to ensure that the air temperature before entering the lower tower as low as possible, increase the amount of moisture into the tower air. When the liquid level rises to 2/3 of the normal liquid level, slowly open the liquid nitrogen back to the lower tower valve, slightly open the liquid nitrogen throttle valve.

The key to adjusting the pure stage: ensure that the condensing evaporator liquid oxygen level in the normal range, and the state of stability, timely adjustment of the expander. In order to ensure the efficient operation of one expander, the other expander gradually reduce the amount until it stops. Liquid-air throttle valve, liquid nitrogen throttle valve and liquid nitrogen back down the tower valve switch to slow, cut to have foresight. When using the liquid-air throttle valve to control the lower tower liquid-air level, use the liquid-nitrogen throttle valve to control the lower tower liquid-air and liquid-nitrogen purity. According to the oxygen purity gradually open up the oxygen delivery valve to normal value. Adjust the nitrogen outlet valve and dirty nitrogen outlet valve to gradually increase the nitrogen purity to the normal index under the premise of ensuring the stability of the upper tower pressure. When the oxygen and nitrogen product purity reaches the target, adjust the expander air into the upper tower gas volume to increase the product output. Seize the important link of liquid oxygen level stability during normal operation and adjust the amount of cold production in time.

Dear Air has many years of experience in manufacturing small air separation units and large air separation units, focusing on all aspects to ensure the overall stable operation of liquid air separation plants.

缅甸1500空分冷箱

DEAR Air Separation Solve YourSmall air separation units start-up operation accumulation You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top