Self-cleaning air filter in small air separation unit

Self-cleaning air filter in small air separation unit
Mar 21, 2022
Author: DEAR AST

(1) In the box combination installation, the combined part of the clean air chamber should pay attention to.

(2) welding form must be the net air chamber around the welding of the sealing welding in small air separation unit(i.e. full welding), no intermittent welding.

(2) If the combination of gasket in the middle of the chamber is used, the bolts and nuts of the combination should be tightened. and sealed by injecting glass glue at the seam of the splice.

(3) When installing the filter box, the nuts at the end of the fixing bracket must be tightened and must not be loosened.

(4) After the installation of each box combination in small air separation unit, attention should be paid to check whether there is a carved bruise in the installation, if (4) After the installation of each box combination, attention should be paid to check whether there are any bruises in the installation, and if so, the primer and top coat should be applied in time.

(5) After installation, use a hoover or other apparatus to thoroughly clean up the debris, welding slag and dust in the gas chamber sink box (or gas collection box).

(6) Check that the maintenance manhole on each level is tightly covered and sealed.

When installing small air separation unit, Dear Air Separation checks the control program of the controller in accordance with the requirements of the instruction manual, and check whether the differential pressure controller is connected to the controller, the action of the solenoid valve diaphragm and the signal connection of the DCS system. For areas with many thunderstorms, lightning protection and earthing measures must be installed.

生物能源3

DEAR Air Separation Solve YourSelf-cleaning air filter in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top