当前位置: Home / Faq / Small air separation FAQ /

Self-cleaning air filter in small air separation unit

Self-cleaning air filter in small air separation unit
Mar 21, 2022
Author: DEAR AST

(1) In the box combination installation, the combined part of the clean air chamber should pay attention to.

(2) welding form must be the net air chamber around the welding of the sealing welding in small air separation unit(i.e. full welding), no intermittent welding.

(2) If the combination of gasket in the middle of the chamber is used, the bolts and nuts of the combination should be tightened. and sealed by injecting glass glue at the seam of the splice.

(3) When installing the filter box, the nuts at the end of the fixing bracket must be tightened and must not be loosened.

(4) After the installation of each box combination in small air separation unit, attention should be paid to check whether there is a carved bruise in the installation, if (4) After the installation of each box combination, attention should be paid to check whether there are any bruises in the installation, and if so, the primer and top coat should be applied in time.

(5) After installation, use a hoover or other apparatus to thoroughly clean up the debris, welding slag and dust in the gas chamber sink box (or gas collection box).

(6) Check that the maintenance manhole on each level is tightly covered and sealed.

When installing small air separation unit, Dear Air Separation checks the control program of the controller in accordance with the requirements of the instruction manual, and check whether the differential pressure controller is connected to the controller, the action of the solenoid valve diaphragm and the signal connection of the DCS system. For areas with many thunderstorms, lightning protection and earthing measures must be installed.

生物能源3

DEAR Air Separation Solve YourSelf-cleaning air filter in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What precautions should be taken when designing a complete set of air separation equipment?
2024.11.22
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top