当前位置: Home / Faq / Liquefied air separation FAQ /

How to arrange the piping in the liquid tank area of liquid air separation plant?

How to arrange the piping in the liquid tank area of liquid air separation plant?
Feb 26, 2026
Author: DEAR AST

Liquid air separation plant liquid hub area piping arrangement is mainly oxygen, nitrogen, argon liquid pipeline and pump box in the liquid pipeline arrangement. As oxygen, nitrogen, argon liquid temperature is extremely low (liquid oxygen -183 ° C ℃, liquid nitrogen -196 ° C, argon liquid -185.7C), in the liquid flow process, resulting in a certain amount of gasification, piping should pay attention to the slope of the liquid pipeline towards (no slope requirements on the process).

In the design of liquid air separation plant for liquid air, there are many requirements for the piping of liquid pipelines, and attention should be paid to the design standards and specifications of liquid air enterprises. In the pipeline of the cryogenic liquid pump inlet, no gas pockets (although the height of the gas pockets should be lower than the bottom of the cryogenic liquid storage tank) or liquid pockets should be formed. Once an air pocket or liquid pocket is formed, the cryogenic liquid air separation plant pump cannot be started normally, and even if it can be started normally, it will cause cavitation of the cryogenic liquid pump and shorten the life of the pump. Pump box piping is also the same, the pump inlet piping as short as possible, pump box wall to use bubble glass brick to low temperature piping and carbon steel pump box separated, if not done well, low temperature liquid through the pump box will form frost on the outside of the pump box, so that the loss of cold caused by low temperature liquid vaporization. All supports inside the pump tank are made of stainless steel and separated by red pine blocks.

Dear air separation equipment manufacturing and piping production has a wealth of experience, in the design process, process, piping and stress professional close cooperation, so that the safety and economy of liquid air separation plant and piping design to achieve perfect unity.

秦皇岛安丰钢铁有限公司-KDON(Ar)-3000070000-900型空分设备

DEAR Air Separation Solve YourHow to arrange the piping in the liquid tank area of liquid air separation plant?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The comprehensive energy-saving transformation of cryogenic air separation is not a single point of equipment replacement, but a collaborative optimization of the whole system, which mainly covers six technical sectors: 1. optimization of compressed air supply system: frequency conversion/permanent magnet transformation of air compressor, matching of air supply pressure, reducing the loss of venting and depressurization, solving the problem of "big horse pulling small car", and the compression link accounts for more than 70% of the total energy consumption of air separation, which is the focus of energy conservation; 2. transformation of precooling and purification system: high efficiency and low resistance molecular sieve, adaptive regeneration control, air inlet precooling, reduce regeneration energy consumption and system resistance, and reduce compressor load; 3. upgrading of rectification and main heat exchange system: efficient and regular packing, optimization of reflux ratio, o
2026.11.20
Answer:>>the conventional air separation unit of DEAR air separation plant is designed for 20 years, which meets the design service life recommended by national standards and specifications, and is also the cost-effective optimization scheme for bot/boo gas investment and long-term stable gas consumption projects. The default recommended design service life of the national standard and relevant specifications, feasibility study, bidding and preliminary design drawings of pressure vessels is 20 years. Designed for 20 years: the cold box plate, heat exchanger and pressure bearing parts are of higher material selection grade, suitable for long-term continuous operation, and suitable for bot/boo gas investment, metallurgy and chemical industry long-term gas supply projects; The maintenance is in place and the technical transformation is timely. The actual stable service can reach 20-25 years, and the working condition management can reach 28-30 years. 15 years of design: moderate investmen
2026.11.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top