当前位置: Home / Faq / Small air separation FAQ /

Selection of the VPS pre-treatment solution in small air separation unit

Selection of the VPS pre-treatment solution in small air separation unit
Jul 28, 2025
Author: DEAR AST

The adsorbent can adsorb and desorb small molecules such as H, N2.CH, C0. C02.02 etc. under operating conditions, but it is difficult to desorb liquid, sulphide and many large molecules such as high hydrocarbons (Cs+), tar, naphthalene, benzene etc. after adsorption. These substances are equivalent to 'toxic substances' for the adsorbent, once the adsorbent is adsorbed the adsorbent will not be able to desorb and regenerate in time, or cannot be completely desorbed, the adsorbent will lose its activity, which will lead to a significant drop in the performance of the VPS small air separation units (processing capacity, product purity, etc.) and prevent normal operation; at the same time some substances such as naphthalene will also block the bed after agglomeration, resulting in an increase in pressure drop. Therefore, if these impurities are present before the raw gas enters the VPS small air separation units, pre-treatment of these impurities to remove them and protect the adsorbent in order to maintain a long and stable operation of the VPS unit is a necessary measure.

Dear Air separation 's VPS pre-treatment solutions meet a variety of needs and establish good long-term relationships with our customers.

DEAR Air Separation Solve YourSelection of the VPS pre-treatment solution in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the air separation unit, low-temperature liquid is transported by centrifugal cryogenic pump. In order to ensure the reliable operation of the equipment, two sets of low-temperature pumps are generally equipped, one for use and one for standby. During normal operation, the main pump runs at full load, and the standby pump is in standby state under low load operation. Since the working medium temperature of cryogenic liquid pump is about -180°C, the working pressure is very high, and the pump body is installed in the cold box. When the pump fails, it is extremely difficult to maintain. Therefore, how to maintain the stable and reliable operation of cryogenic liquid pump is of great significance.
2025.09.03
The brief introduction of the air filter and air compressor in this process is the same as that of the chilled nitrogen production process. 1. Cold dryer: it is an air separation equipment used to reduce the temperature of compressed air before entering the air drying purifier to extract oil and water. It usually adopts post cooler with the structure of column pipe type, casing type, cooling sheet type and so on. 2. Oil-water separator: its function is to separate the oil and moisture contained in the compressed air and make the compressed air get Primary purification. 3. Air drying purifier: Compressed air still contains certain moisture after passing through the post cooler, and its content depends on the temperature of the air. The drying process of compressed air generally adopts molecular sieve absorption method and freeze drying method. 4. Pressure conversion absorption nitrogen generation device: the adsorbents used are usually 5A Molecular sieve or carbon molecular sieve, an...
2025.09.02
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top