The future of the liquid air separation plant cold energy industry

The future of the liquid air separation plant cold energy industry
Oct 31, 2025
Author: DEAR AST

Traditional LNG receiving stations use seawater open-frame vaporisers or submerged combustion vaporisers to vaporise LNG, which not only wastes valuable cold energy but also produces localised low temperature pollution of the nearby sea. The air separation temperature range is between -190C - 150C and the LNG vaporisation temperature is -162C, which matches the liquid air separation plant temperature range. The use of LNG's high quality low temperature cold energy for liquid air separation plant can significantly reduce energy consumption according to the temperature zone gradient, which is part of the energy saving and resource reduction advocated by the state.

Dear air separation's latest generation of intelligent liquid air separation plant combined with Dear air separation has the advantage of energy-saving technology, compared with traditional liquid air separation plant energy consumption can be reduced by an average of 15%, saving customers tens of millions of dollars per year.

微信图片_20200217112035

DEAR Air Separation Solve YourThe future of the liquid air separation plant cold energy industryYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top