Heat transfer temperature difference for main cooling in small air separation unit

Heat transfer temperature difference for main cooling in small air separation unit
Jun 05, 2026
Author: DEAR AST

In the condensation evaporator the liquid oxygen is heated to evaporate and the gas nitrogen is cooled and condensed. Both the liquid oxygen and the gas nitrogen are in a saturated state. If the saturation temperature of nitrogen is lower than the saturation temperature of oxygen at the same pressure, the purpose of condensing gas and nitrogen with liquid oxygen cannot be achieved. For this reason the heat transfer temperature difference in the condensing evaporator in small air separation unitmust be established by the pressure difference. Raising the pressure in the lower tower to increase the saturation temperature of the nitrogen is the only way to achieve a suitable heat transfer temperature difference between the liquid oxygen and the gas nitrogen and to achieve the purpose of condensing the gas nitrogen with liquid oxygen in small air separation unit.

For a long time, Dear Air Separation has been adhering to the principle of contract compliance and trustworthiness, and has achieved fruitful results over the years, has a number of loyal customer groups, and has won a good reputation in the air separation industry.

云南红河红铅有色化工有限公司-4500

DEAR Air Separation Solve YourHeat transfer temperature difference for main cooling in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When there is no pressure signal input, the valve is closed; when there is a pressure signal, the valve starts to open, and the larger the input signal, the larger the valve opening, this kind of film regulating valve is called air-opening film regulating valve in small air spearation unit. When there is no pressure signal input, the valve is fully open, and when there is a pressure signal input, the valve starts to close; the larger the input signal, the smaller the valve opening; when the inp...
2026.07.29
What is the cause of ultra low temperature in air separation plant and the principle of refrigeration equipment?
2026.07.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top