Heat transfer temperature difference for main cooling in small air separation unit

Heat transfer temperature difference for main cooling in small air separation unit
Jun 05, 2026
Author: DEAR AST

In the condensation evaporator the liquid oxygen is heated to evaporate and the gas nitrogen is cooled and condensed. Both the liquid oxygen and the gas nitrogen are in a saturated state. If the saturation temperature of nitrogen is lower than the saturation temperature of oxygen at the same pressure, the purpose of condensing gas and nitrogen with liquid oxygen cannot be achieved. For this reason the heat transfer temperature difference in the condensing evaporator in small air separation unitmust be established by the pressure difference. Raising the pressure in the lower tower to increase the saturation temperature of the nitrogen is the only way to achieve a suitable heat transfer temperature difference between the liquid oxygen and the gas nitrogen and to achieve the purpose of condensing the gas nitrogen with liquid oxygen in small air separation unit.

For a long time, Dear Air Separation has been adhering to the principle of contract compliance and trustworthiness, and has achieved fruitful results over the years, has a number of loyal customer groups, and has won a good reputation in the air separation industry.

云南红河红铅有色化工有限公司-4500

DEAR Air Separation Solve YourHeat transfer temperature difference for main cooling in small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top