When using sieve plate towers for distillation, the liquid must be covered with a certain height of liquid layer in order to exchange heat and mass with the rising gas. In contrast, a packed tower only needs to wet the packing surface to form a liquid film for heat and mass exchange. Therefore, the liquid holding capacity of a packed tower is much smaller than that of a sieve plate tower, and the packed tower can also establish distillation conditions more quickly.

The Henan Province Air Separation Engineering Technology Research Centre, based on Dear Air Separation Design Institute, was established in 2018. The centre brings together a number of well-known experts and technical elites in the air separation industry, providing a platform for technological innovation, project development and sharing of results in design small air separation unit, large air separation unit and liquid air separation plant.

旋转-DSC03535

DEAR Air Separation Solve YourLiquid holding capacity of packed and sieve plate towers of small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top