当前位置: Home / Faq / Liquefied air separation FAQ /

New single column process of liquid air separation plant

New single column process of liquid air separation plant
Oct 16, 2025
Author: DEAR AST

There is an open heat pump argon extraction process.

 

The new single column process can only use the open heat pump argon extraction process. Taking 10000cm³ air separation as an example, the main parameters are described as follows.

 

1、 The quantity of argon fraction is 4200-4300cm3 / h, the content of argon is 10%, the content of nitrogen is 1%, and the rest is oxygen.

 

2、 The theoretical plate number of the whole column is about 100.

 

3、 Two heat pump distillation processes are adopted, one is the heat pump with crude argon as the circulating working fluid, the other is the heat pump with argon fraction containing 25% (which can be selected in a certain range) of argon as the circulating working fluid. The compression capacity of crude argon is 7500cm3 / h, the compression ratio is 2, and the compression power consumption is 65kW. The compression capacity of 25% argon fraction is 5000cm3 / h, the compression ratio is 1:4, and the compression power consumption is 25kW.

 

4、 The condensers of crude argon and 25% argon fraction are set at the bottom of the distillation column. The condensate of crude argon enters from the top of the distillation column, and the condensate of 25% argon fraction enters from the middle of the distillation column.

 

5、 The bottom of the distillation column produces 4000 cm3 / h oxygen with 99.5% purity and 0.5% argon. The crude argon produced at the top of the column is 440cm3 / h, containing 10% nitrogen and 1ppm oxygen.

 

DEAR Air Separation design and Research Institute: make great efforts to make breakthroughs. Employ high-end talents; Won a number of patents; Help customers grow.

 

DEAR Air Separation has been focusing on the manufacturing and service of small air separation unit and large air separation unit and liquid air separation plant for nearly 20 years. It has rich experience in project engineering, and constantly uses innovative technologies to optimize unit energy saving and safety. DEAR Air Separation strives to bring higher benefits to customers.

朱克嘉-凌云(缅甸1500)

DEAR Air Separation Solve YourNew single column process of liquid air separation plantYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top