Measures to avoid cavitation in centrifugal pumps of small air separation unit

Measures to avoid cavitation in centrifugal pumps of small air separation unit
May 26, 2026
Author: DEAR AST

The cavitation of centrifugal pumps is very harmful. It causes great stress on the surface of the impeller and also reduces the head of the pump of small air separation unit, increases the power and reduces the efficiency. Therefore, measures should be taken in the process of use to avoid cavitation as far as possible. In order to avoid cavitation of small air separation unit, in the process design, should make the liquid into the pump before a certain degree of subcooling, while the pump body should be installed in a lower position, to maintain a certain static pressure of the liquid inlet. In addition to this, attention should be paid to the preservation of cooling to reduce cold loss.

Dear Air has always been guided by customer needs, creating a new value chain of services. Based on our long experience, we have formed a whole set of effective pre-sales, in-sales and after-sales support service system to help customers to carry out all the work smoothly.

纯氮空分设备-(1)

DEAR Air Separation Solve YourMeasures to avoid cavitation in centrifugal pumps of small air separation unitYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top