Advantages of the nitrogen cycle process of liquid air separation plant

Advantages of the nitrogen cycle process of liquid air separation plant
Jul 20, 2023
Author: DEAR AST

The advantage of using this process design is that the nitrogen cycle compressor and the medium/high/ultra-high pressure product nitrogen press are combined into one machine, eliminating the need to use multiple product nitrogen presses. Due to the high nitrogen to oxygen ratio, a portion of the nitrogen must be extracted from the top of the low pressure tower to make up the nitrogen cycle compressor. This make-up compressor is also combined with the low-pressure/low-pressure product nitrogen press.

Due to the highly targeted and optimized design, this liquid air separation plant uses only two nitrogen compressors to solve the oxygen in-compression process required for the production of cold volume, pressure liquid oxygen reheat and five different pressure nitrogen products, simplifying the process and saving equipment investment. It is worthy of being a very classic process design.

6

DEAR Air Separation Solve YourAdvantages of the nitrogen cycle process of liquid air separation plantYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When the main condenser evaporator leaks seriously, a large amount of high-pressure nitrogen will leak to the low-pressure oxygen side, and the pressure of the upper and lower columns and the purity of the product will change significantly until normal production cannot be maintained. When the main condenser evaporator leaks slightly, the pressure of the upper and lower columns will not change significantly, and the purity of liquid oxygen in the main condenser evaporator will not decrease significantly. The common phenomenon is that the purity of the gas and liquid oxygen in the main condensing evaporator is very different, and the gas concentration is lower than that in equilibrium with liquid oxygen. For example, the concentration of liquid oxygen is 99% and that of gaseous oxygen is 96%, that 7 main cooling pipes were found to be leaking during maintenance. The common causes of leakage are as follows: 1. Pipes are worn due to mutual vibration. For long tube condensing evap
2025.11.25
How to prevent scaling of cooling system of air separation equipment?
2025.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top